8000077 Rev 1    PSDIN User Guide     

 

  Subject to change without notice   

 

Page 

2

  of 

Removal from DIN Rail: 

Insert a flat screwdriver into the slot in the DIN rail bracket. Pull down on the clamp 

to release the unit from the DIN rail.

 

 

3. Front Panel

 

Operation indicator

 

Indicates whether the unit is working properly. Green LED (“DC-OK”) is lit if the voltage at the output terminal 
is more than 45V. Red LED (“Overload”) will light when output is in fault condition.

 

DC Adjust Potentiometer

 

Output Voltage can be adjusted to suit individual application needs. The adjustment range is 47VDC to 56VDC.

 

Single/Parallel Use Switch

 

The power supply units can be operated standalone  (“Single Use”)  or ganged (“Parallel Use”) in order  to 
provide additional power. When in parallel mode the outputs are connected together in parallel (+ to + and 
– to –)to feed the load. Two 120W power supplies in parallel mode provide up to 240W of power to the load. 
DO NOT change the Single/Parallel switch position while the unit is powered up. Please disconnect power 
before changing the mode to avoid damage to the unit.

 

“DC” and “OK” Connection

 

The DC and OK connections at the top of the unit are a dry contact relay which is CLOSED when the DC output 
is normal and OPEN when the DC output is in a fault condition. Contact rating is 1A @ 30VDC or 0.5A at 
125VAC. This is useful to trigger an alarm if the DC output fails.

 

 

4. Connections / Internal fuse

 

 

There is an internal 5A fuse on the AC input. This is not designed to be user serviceable.

 

 

Use only commercial quality cables designed for the indicated voltage and current values!

 

 

When using stranded cables, be sure all strands are secure inside the wire terminal connector.

 

 

Ensure proper polarity at the output terminals! There are two – and two + terminals for convenience.

 

 

Do not operate without proper ground connection! A proper ground is required to comply with EMC 
and safety standards. To ground the chassis, use one of the case screws on the back of the unit or the 
separate ground screw on the bottom of the unit (if applicable).

 

 

Specifications

 

 

 

PSDIN-48-120W 

PSDIN-48-240W 

Input Operating Range

 

90-264VAC ;    47-63Hz 

AC In-rush Current

 

35A Max 

Input Current

 

2.2A @115VAC ; 1.10A @230VAC 

4.4A @115VAC ; 2.20A @230VAC 

Output Voltage 

 

47~ 56VDC (adjustable) 

Cont. Load Current

 

2.5A 

5A 

Max Output Power

 

120W 

240W 

Peak Power (10sec)

 

180W 

360W 

Ripple / Noise

 

100mV Peak 

Efficiency

 

90% Minimum 

Protection

 

Short Circuit, Over-Voltage, Over-Current, Over Power 

Alarm Output (DC & OK)

 

1A @ 30VDC, 0.5A @ 125VAC. DC OK = Closed, DC Fault = Open 

Operating Temp

 

-40°C to 70°C (-40°F to 158°F)   

Note: de-rate to 50% power at 70C

 

Operating Humidity

 

5% to 95% non- condensing 

Storage Temp

 

-40°C to 85°C (-40°F to 185°F) 

MTBF

 

200,000 hrs 

Altitude

 

2000m (6562ft) 