background image

  

 

TPDIN-SC48-20 

MPPT Solar Controller 

with Passive PoE Switch 

▫ 

Wireless Base Stations 

and Client Devices 

▫ 

Surveillance Cameras 

▫ 

Remote Control 

▫ 

Remote Lighting 

▫ 

Off Grid Electronics 

Congratulations! 

on your purchase of the TPDIN-SC48-20 

20A MPPT Solar Controller with 7 Port Gigabit Passive PoE 

Switch. Please take a moment to review this Qwik Install Guide 

before use. 

Operation Modes: 

Solar Only operation, Solar with DC Back-

up, DC Only operation. 

Key Features: 

Industrial Strength, Manageable, 24VDC or 

48VDC Output, 7 Gigabit Passive PoE ports, 48V 20A MPPT So-

lar, Automated Alerts, Removable Connections 

Safety: 

For your own protection, follow these safety rules. 

▫ 

Perform as many functions as possible on the ground 

▫ 

Do not attempt to install on a rainy, windy or snowy day or if 

there is ice or snow accumulation at the install site or if the 

site is wet. 

▫ 

Make sure there are no people, pets, etc. below if you are 

working on a roof or ladder.

 

Recommended Tools: 

 Small Flat Blade Screwdriver, Phil-

lips Screwdriver

 

Please help preserve the environment and return 

any used batteries to an authorized depot 

Summary of Contents for TPDIN-SC48-20

Page 1: ...y Features Industrial Strength Manageable 24VDC or 48VDC Output 7 Gigabit Passive PoE ports 48V 20A MPPT So lar Automated Alerts Removable Connections Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet Ma...

Page 2: ... off until the settings are changed in the web user interface STEP 5 If you will be using the Aux Output connect your load wires to the Small Green 2 Pin Connector Be sure the wire connections are tight Be sure the voltage polarity is correct Plug the Aux connector into the Aux Output socket If you won t be using the Aux Output just plug the empty connector back into the socket STEP 6 Connect Ther...

Page 3: ...ile options and set IP address options Load Power Enable or disable all power to the loads This disa bles all output power and overrides all other port power settings Save Port Names Customize names for each port like CAM1 WIFI PUMP FAN BHAUL etc There is a 6 character limit Set Port Startup States Set each ports default startup state OFF 24Vor 48V This is the state the port will revert to after a...

Page 4: ... Power Off and Power On Volts When the battery voltage falls below the Power Off voltage the load is turned off and when it rises above the Power On voltage the load is turned back on We recommend using the default values Set temperature default as deg F or C Network Settings Set IP Address to DHCP or Static Set Host Name The host name will show in the discovery tool and the browser tab This can h...

Page 5: ...P 11 The Monitor Page is the main status and port control page Port voltage can be changed and ports can be turned On or Off manually or they can be cycled Battery Voltage Shows the present battery voltage Battery Current Shows current flowing into or out of the battery A positive current means the battery is charging A negative current means the battery is discharging Input Voltage Shows the sola...

Page 6: ...Maximum Battery Voltage 48VDC Fuse Type 58V Fast Blo Auto Blade Type Littlefuse 142 6185 5206 Low Voltage Disconnect 45 8V to 47 8V Low Voltage Disconnect recovery 48 1V to 49 2V Battery Type GEL or AGM External DC Input 62V to 75VDC 3A External DC Input Connector 4p mini DIN PoE Switch Qty 7 10 100 1000Mb PoE Output Power Numbers shown are for 48V PoE Divide by 2 for 24V PoE Port 1 3 35W Passive ...

Page 7: ...nput won t be used unless there is no sun UPS non solar Operation The unit can also be used as a high powered UPS or battery backup system by providing 65VDC 18A into the PV and inputs Tycon offers a AC to DC power supply to ac complish this SNMP The controller can be accessed via HTTP or SNMP SNMP enables remote management via an SNMP control server MIB file can be found at http tyconsystems com ...

Page 8: ...s supplied with a limited 24 month warranty which covers material and workmanship defects This warranty does not cover the following Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning or weather damage Physical damage to the external internal parts Products that have been opened altered or defaced Water damage Usage other than in accorda...

Reviews: