Qwik Install 

STEP 1:

 

Remove Large 4 Pin and Small 2 Pin Green connectors from 

the top of the unit. 

STEP 2:

 

Attach the TPDIN-SC48-20 to a DIN Rail mount. To mount to 

a flat plate remove the DIN Rail bracket from the back by removing 5 

screws and mount to a plate using the two wall mount tabs provided. 

There is a green ground screw for connecting one of the tabs to earth 

or chassis ground. 

Important! 

Please make sure that the air flow to the 

bottom and top of unit is not blocked or unit may overheat and shut 

down. 

Note: 

The Unit is removed from the DIN rail by pushing up on the 

unit and at the same time moving the bottom of the unit forward.

 

STEP 3:

 

 

Attach 48VDC battery wires (BAT+ and BAT-) and solar panel 

wires (PV+ and PV--) to the Large Green connector.  Make sure the 4 

connections are tight in the connectors and not clamping on wire insula-

tion. 

IMPORTANT! Make sure the polarity is correct. Damage to the unit 

can occur if polarity is reversed.

 

STEP 4:

 

Plug Large Green connector into the top of the controller. The 

Charging LED on the front panel should light for about 60 sec. 

Note: 

All LED’s except the Charging LED will initially be off until the 

settings are changed in the web user interface. 

STEP 5:

 

If you will be using the Aux Output, connect your load wires to 

the Small Green 2 Pin Connector. Be sure the wire connections are 

tight. Be sure the voltage polarity is correct. Plug the Aux connector into 

the Aux Output socket. If you won’t be using the Aux Output, just plug 

the empty connector back into the socket.

 

STEP 6:

 

Connect Thermocouple cable to the 2 pin green connector. 

The Thermocouple does not have a polarity. Connect the Thermocou-

ple cable assembly ring lug to one of the battery terminals. It can be 

connected to the + or - terminal. Plug the thermocouple 2 pin green 

connector to the socket labelled “Temp Sensor”.

 

STEP 7:

  There is an amber LED which will light on any PoE port 

that is powered. If the amber LED is off it means the power is off to that 

port. By default all ports are off. Connect your network or PC to one of 

the unpowered ports.  

STEP 8: 

The default IP address is 192.168.1.6  The unit may also 

get an IP address from a DHCP server. We have a free discovery tool 

available at 

http://tyconsystems.com/index.php/support/tpdin-firmware

 

  This tool will find the controller no matter what IP address it is on, even 

across subnets. Your computer IP address will need to be on the same 

subnet as the controller in order to access the web browser control pan-

Summary of Contents for TPDIN-SC48-20

Page 1: ...y Features Industrial Strength Manageable 24VDC or 48VDC Output 7 Gigabit Passive PoE ports 48V 20A MPPT So lar Automated Alerts Removable Connections Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet Ma...

Page 2: ... off until the settings are changed in the web user interface STEP 5 If you will be using the Aux Output connect your load wires to the Small Green 2 Pin Connector Be sure the wire connections are tight Be sure the voltage polarity is correct Plug the Aux connector into the Aux Output socket If you won t be using the Aux Output just plug the empty connector back into the socket STEP 6 Connect Ther...

Page 3: ...ile options and set IP address options Load Power Enable or disable all power to the loads This disa bles all output power and overrides all other port power settings Save Port Names Customize names for each port like CAM1 WIFI PUMP FAN BHAUL etc There is a 6 character limit Set Port Startup States Set each ports default startup state OFF 24Vor 48V This is the state the port will revert to after a...

Page 4: ... Power Off and Power On Volts When the battery voltage falls below the Power Off voltage the load is turned off and when it rises above the Power On voltage the load is turned back on We recommend using the default values Set temperature default as deg F or C Network Settings Set IP Address to DHCP or Static Set Host Name The host name will show in the discovery tool and the browser tab This can h...

Page 5: ...P 11 The Monitor Page is the main status and port control page Port voltage can be changed and ports can be turned On or Off manually or they can be cycled Battery Voltage Shows the present battery voltage Battery Current Shows current flowing into or out of the battery A positive current means the battery is charging A negative current means the battery is discharging Input Voltage Shows the sola...

Page 6: ...Maximum Battery Voltage 48VDC Fuse Type 58V Fast Blo Auto Blade Type Littlefuse 142 6185 5206 Low Voltage Disconnect 45 8V to 47 8V Low Voltage Disconnect recovery 48 1V to 49 2V Battery Type GEL or AGM External DC Input 62V to 75VDC 3A External DC Input Connector 4p mini DIN PoE Switch Qty 7 10 100 1000Mb PoE Output Power Numbers shown are for 48V PoE Divide by 2 for 24V PoE Port 1 3 35W Passive ...

Page 7: ...nput won t be used unless there is no sun UPS non solar Operation The unit can also be used as a high powered UPS or battery backup system by providing 65VDC 18A into the PV and inputs Tycon offers a AC to DC power supply to ac complish this SNMP The controller can be accessed via HTTP or SNMP SNMP enables remote management via an SNMP control server MIB file can be found at http tyconsystems com ...

Page 8: ...s supplied with a limited 24 month warranty which covers material and workmanship defects This warranty does not cover the following Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning or weather damage Physical damage to the external internal parts Products that have been opened altered or defaced Water damage Usage other than in accorda...

Reviews: