nect the battery cable to the Large Green Connector battery inputs and 

then to the batteries making sure to observe the proper polarity. 

 

STEP 7:

  Install the cable glands in the back of the enclosure and route 

the long solar panel cables through the cable gland and connect to the 

large green connector solar (PV) inputs. You can shorten the cables as 

necessary for a cleaner install. You can also lengthen the cables by 

adding additional lengths of 12AWG cable. Please note that the longer 

the cable, the more cable loss you will see.

 

STEP 8:  

Connect the solar panels in series (Positive to Negative) by 

plugging the positive from panel 1 to the negative of panel 2 and then 

connect the  long 

20’ 

solar cable to the remaining positive and negative 

connectors from the solar panels. The connectors are keyed for polarity 

so they cannot be connected incorrectly.  

 

Summary of Contents for RemotePro RPAL48

Page 1: ...Port 48V 20A MPPT Solar Automated Alerts Removable Connec tions Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet Make sure there are no people pets etc below if you are working on a roof or ladder Recom...

Page 2: ...teries STEP 4 Place battery box under solar panels Install 4 batteries in the box Use handles to lower batteries into the box Remove the battery fuse from the battery cable before proceeding Connect all 4 batter ies in series configuration Positive to Negative to Positive STEP 5 Install DIN rail to enclosure using the two screws provided Install MPPT solar controller to DIN Rail Remove the Large G...

Page 3: ...can shorten the cables as necessary for a cleaner install You can also lengthen the cables by adding additional lengths of 12AWG cable Please note that the longer the cable the more cable loss you will see STEP 8 Connect the solar panels in series Positive to Negative by plugging the positive from panel 1 to the negative of panel 2 and then connect the long 20 solar cable to the remaining positive...

Page 4: ...n If desired attach the enclosure to the solar mount pole using chain or cable for security STEP 13 You may want to put a fine screen over the vent holes on either end of the enclosure to keep out insects Window screen works well Be sure to secure all cables so they won t move in the wind All cable connectors will be protected by being located under the solar panels TECH CORNER Additional Informat...

Page 5: ...ry voltage drops below the level that is setup in the user interface normally around 47V and this will protect the bat tery from over discharge If batteries get completely discharged be cause the equipment was connected directly to the battery you will re duce the battery life and you will most likely need to charge them with a good quality 10A automotive battery charger Once they are back to a no...

Page 6: ...tery cable fuse Check the controller fuse Measure battery voltage at the solar controller it should be 9V If less than 9V then batteries will need to be charged with an external charger to bring the volt age up to normal operating range of the controller NOTES ...

Page 7: ...y Type Valve Regulated Sealed Lead Acid Pure Lead Carbon AGM Battery Life 5 Years Controller Type 48V 20A MPPT Battery Charge Control ler with 7 port Gigabit PoE switch and remote management Over discharge protection 45 8V to 47 8 settable in web interface Over discharge recovery volts 48 1V to 49 2V settable in web inter face Controller Self Consumption 3 5W Typical Enclosure Type Diamond Plate A...

Page 8: ... replacement due to improper installation misuse poor site conditions faulty power etc Lightning or weather damage Physical damage to the external internal parts Products that have been opened altered or defaced Water damage Usage other than in accordance with instructions and the normal intended use Tycon Systems Inc 14641 S 800 W Suite A Bluffdale UT 84065 support tyconsystems com PH 801 432 000...