background image

5

 

 

CAUTION: 

Be sure to connect the battery to the controller first and dis-

connect it last. Connecting solar panels to the controller without the bat-

tery connected could damage the controller.

 

Summary of Contents for RemotePro RPS 12

Page 1: ...with overhead power lines lights and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the instal...

Page 2: ...is towards the top or side Connect the solar panel MC 4 connectors in series configuration TIP We strongly recommend installing the batteries and other equip ment in the enclosure after mounting the enclosure to the pole or wall STEP 3 Attach top and bot tom brackets to the enclosure STEP 4 Mount the enclosure to a pole using U Bolts and or 4 hose clamps The enclosure can also be wall mounted us i...

Page 3: ...of the MPPT controller and mount the MPPT control ler to the DIN rail mounted on the en closure door STEP 12 Double check wiring and then re install the battery cable fuse to energize the system The MPPT controller will power up and automatically detect the battery configura tion The display is activated by vibration so to turn on the display tap the glass cover Once the controller is energized co...

Page 4: ...4 MC 4 Connectorized Panels Wiring Configurations using MPPT Controllers Two Panel Configuration for 12V or 24V Battery Configurations Four Panel Configuration for 12V or 24V Battery Configurations ...

Page 5: ...5 CAUTION Be sure to connect the battery to the controller first and dis connect it last Connecting solar panels to the controller without the bat tery connected could damage the controller ...

Page 6: ... 5V This protects battery from overdischarge and increases battery life and performance 2 Fuse There is a fuse in the battery cable 30A The fuse is in line with battery power If fuse is blown there was some sort of short in the battery connection and the controller will appear dead Replace with a 30A fuse 3 CAPACITY The RemotePro is rated at 25W to 50W continuous power output with 6 hours of peak ...

Page 7: ...batteries get completely discharged 10V because the equipment was connected directly to the battery you will reduce the battery life and you will most likely need to recondition them with a good quality 10A automotive battery charger Avoid charging for longer than 24hrs to avoid battery damage Once they are back to a normal operating range the integrated charge controller will maintain the charge ...

Page 8: ...re Type Powder Coat Aluminum Wind Survivability 90MPH Operating Temperature 30 C to 60 C Limited Warranty The RemotePro products are supplied with a limited 36 month warran ty which covers material and workmanship defects This warranty does not cover the following Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning or weather damage Physi...

Reviews: