background image

 

Qwik Install

 

STEP 1:

 

The UPSPro

® 

i s Solar Ready™ so a solar panel can be add-

ed at any time to provide supplemental or full time power. 

STEP 2:

 

Install controller to inside cover of housing using Velcro tape. 

Be sure that controller doesn’t interfere with batteries when cover is 

closed. Mount all the way to lower right corner to give room for CAT5 

cables. 

STEP 3:

 

 

Mount any electronics boards to the metal plate. Install a 

CAT5 cable between the controller POE OUT and the electronics. 

There is a secondary voltage output on the back of the controller which 

can be used in addition to the POE OUT. The secondary output is equal 

to the battery voltage.  

STEP 4:

 

Install the enclosure to a pole using stainless steel hose 

clamps or to a wall using lag bolts. 

STEP 5:

 

Install batteries into enclosure with Velcro straps. 

STEP 6:

 

Connect the Battery cables to Controller BAT terminals. Be 

sure to observe polarity. Black wire connects to battery negative termi-

nal and BAT(-) terminal on the controller. When a fully charged battery 

is connected, the Green LOA LED should light on controller. Power 

should also be present at the POE output and the green secondary 

power output. 

STEP 7:

 Install CAT5 cable between POE inserter/Power Supply inside 

building and the UPSPro

® 

unit controller RJ45 IN connector. It is highly 

Summary of Contents for UPSPro UPS-PL

Page 1: ...hts and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet ...

Page 2: ...er which can be used in addition to the POE OUT The secondary output is equal to the battery voltage STEP 4 Install the enclosure to a pole using stainless steel hose clamps or to a wall using lag bolts STEP 5 Install batteries into enclosure with Velcro straps STEP 6 Connect the Battery cables to Controller BAT terminals Be sure to observe polarity Black wire connects to battery negative termi na...

Page 3: ...ear of the seam and hinge area The cover snaps into place There is one center security bolt that can be used to secure the cover NOTE If you have any unconnected battery connectors on battery cable after installation make sure they are wrapped with electrical tape so that there is no chance of shorting the connector to any metal You can also remove the extra cable connector permanently by cutting ...

Page 4: ...4 24V Battery Configuration Device 1 Device 2 FG Frame Ground Do Not Connect to V GND V There are two V connec tions 1 and 2 12V or 24V V There are two V connections 1 and 2 ...

Page 5: ...of 12V or 24V 5A Max Solar Panel Size 85W Overcharge Protection 14 4V 28 6V Over discharge protection 11V 20V Over discharge recovery voltage 12V 22V Controller Self Consumption 0 5W POE Power Supply 24V 48V 60W Enclosure Type Polycarbonate Enclosure External Size 17 5 x 12 5 x 6 445 x 318x 152mm Enclosure Internal Size 14 x 10 x 5 356 x 254 x 127mm Space for Customer Electronics 3 x 5 x 3 76 x 12...

Page 6: ...on longitude and is different if summer or winter If the panel won t have seasonal adjust ment set for winter angle and leave this setting year round See tycon power com learning_center for additional information If you are plan ning to keep solar panel angle fixed all year then set the angle to Your_Latitude 0 9 30 7 BATTERY HOOKUP Always connect the battery first and discon nect the battery last...

Page 7: ...voltage sent to the devices So 12VDC in and you get 12VDC POE to the devices The operating voltage is 12V to 56VDC Limited Warranty The UPSPro products are supplied with a limited 24 month warranty which covers material and workmanship defects This warranty does not cover the following Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning o...

Page 8: ...8 8000010 Rev 5 UPS PL UPSPro Qwik Install Guide ...