TECH CORNER

 

 

 

1.

CONTROLLER: 

The controller turns off power to the load at 11V and 

reconnects  when  the  battery  reaches  12V.  This  protects  battery  from 

over-discharge and increases battery life and performance. 

2. 

CAPACITY: 

With  a  typical  AP  running  4W  average.  A  single  12V 

9Ah battery should be able to provide backup power for up to 24 hours 

at room temperature. For cold temperatures the capacity is reduced by 

20-30%. 

3. 

VENTING: 

The enclosure is vented thru the wire feedthrus in the bot-

tom of the enclosure. Don’t make these airtight. 

4.

 DUAL INPUTS: 

The UPS-DC can be used with solar power alone or 

POE power alone or a combination of both. 

5. 

SOLAR  PANEL: 

The  controller  used  in  the  UPS-PL  can  handle  a 

maximum panel size of 135W. Do not exceed 8A into the SOL input or 

damage to the controller can occur. When the solar panel is generating 

power,  the  SOL  input  will  take  priority  and  the  POE  input  will  not  be 

used to charge the battery. When the solar panel isn’t generating power 

then the battery will be charged from the POE input.  

6. 

SOLAR  PANEL  ANGLE: 

Solar  panel  angle  should  be  adjusted  to 

optimize  output.  Optimum  angle  is  based  on  location  longitude  and  is 

different  if  summer  or  winter.  If  the  panel  won’t  have  seasonal  adjust-

ment, set for winter angle and leave this setting year round. See tycon-

power.com/learning_center  for  additional  information.  If  you  are  plan-

ning  to  keep  solar  panel  angle  fixed  all  year  then  set  the  angle  to 

Your_Latitude * 0.9 +30 

7. 

BATTERY  HOOKUP: 

Always  connect  the  battery  first  and  discon-

nect the battery last. The controller should not be run without a battery 

connected. 

8. 

BATTERY MAINTENANCE: 

The batteries used in the UPSPro sys-

tems don’t require any maintenance. They should last up to 5 years in 

normal use.  

Note: Never store batteries for any length of time in a 

discharged state or it will kill the battery. 

 

9. BATTERY OVERDISCHARGE

: We highly recommend hooking all 

equipment loads to the controller voltage output. This output will discon-

nect the load if the battery voltage drops below 11V and this will protect 

the battery from over-discharge. If batteries get completely discharged 

because the equipment was connected directly to the battery, you will 

reduce the battery life and you will most likely need to supercharge 

them with a good quality 10A automotive battery charger. Once they 

are back to a normal operating range, the integrated charge controller 

will maintain the charge.

 

10. 

DUAL  OUTPUTS: 

The  UPS-PL  has  a  POE  output  which  can  be 

Summary of Contents for UPSPro UPS-PL

Page 1: ...hts and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet ...

Page 2: ...er which can be used in addition to the POE OUT The secondary output is equal to the battery voltage STEP 4 Install the enclosure to a pole using stainless steel hose clamps or to a wall using lag bolts STEP 5 Install batteries into enclosure with Velcro straps STEP 6 Connect the Battery cables to Controller BAT terminals Be sure to observe polarity Black wire connects to battery negative termi na...

Page 3: ...ear of the seam and hinge area The cover snaps into place There is one center security bolt that can be used to secure the cover NOTE If you have any unconnected battery connectors on battery cable after installation make sure they are wrapped with electrical tape so that there is no chance of shorting the connector to any metal You can also remove the extra cable connector permanently by cutting ...

Page 4: ...4 24V Battery Configuration Device 1 Device 2 FG Frame Ground Do Not Connect to V GND V There are two V connec tions 1 and 2 12V or 24V V There are two V connections 1 and 2 ...

Page 5: ...of 12V or 24V 5A Max Solar Panel Size 85W Overcharge Protection 14 4V 28 6V Over discharge protection 11V 20V Over discharge recovery voltage 12V 22V Controller Self Consumption 0 5W POE Power Supply 24V 48V 60W Enclosure Type Polycarbonate Enclosure External Size 17 5 x 12 5 x 6 445 x 318x 152mm Enclosure Internal Size 14 x 10 x 5 356 x 254 x 127mm Space for Customer Electronics 3 x 5 x 3 76 x 12...

Page 6: ...on longitude and is different if summer or winter If the panel won t have seasonal adjust ment set for winter angle and leave this setting year round See tycon power com learning_center for additional information If you are plan ning to keep solar panel angle fixed all year then set the angle to Your_Latitude 0 9 30 7 BATTERY HOOKUP Always connect the battery first and discon nect the battery last...

Page 7: ...voltage sent to the devices So 12VDC in and you get 12VDC POE to the devices The operating voltage is 12V to 56VDC Limited Warranty The UPSPro products are supplied with a limited 24 month warranty which covers material and workmanship defects This warranty does not cover the following Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning o...

Page 8: ...8 8000010 Rev 5 UPS PL UPSPro Qwik Install Guide ...

Reviews: