background image

 

12V, 18V, 24V or 48V depending on which model is purchased. There 

is also an auxiliary protected output on the back of the controller to sup-

ply 12VDC. This is useful for applications requiring 2 different voltages. 

11.

 

POE SWITCH: 

Tycon Power offers a universal voltage 5port and 

8port POE switch if more than one device needs to be powered from 

the battery system. The 

TP-SW5-NC 

and 

TP-SW8-NC

 offer the unique 

feature that the voltage supplied to the switch is  the POE voltage sent 

to the devices. So 12VDC in and you get 12VDC POE to the devices. 

The operating voltage is 12V to 56VDC.

 

 

 

Limited Warranty 

The UPSPro

® 

products are supplied with a limited 24 month warranty 

which covers material and workmanship defects. This warranty does 

not cover the following:  

▫ 

Parts requiring replacement due to improper installation, misuse, poor site 
conditions, faulty power, etc. 

▫ 

Lightning or weather damage. 

▫ 

Physical damage to the external & internal parts. 

▫ 

Products that have been opened, altered, or defaced. 

▫ 

Water damage for units that were not mounted according to user manual. 

▫ 

Usage other than in accordance with instructions and the normal intended 

use. 

 

NOTES 

Summary of Contents for UPSPro UPS-PL

Page 1: ...hts and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet ...

Page 2: ...er which can be used in addition to the POE OUT The secondary output is equal to the battery voltage STEP 4 Install the enclosure to a pole using stainless steel hose clamps or to a wall using lag bolts STEP 5 Install batteries into enclosure with Velcro straps STEP 6 Connect the Battery cables to Controller BAT terminals Be sure to observe polarity Black wire connects to battery negative termi na...

Page 3: ...ear of the seam and hinge area The cover snaps into place There is one center security bolt that can be used to secure the cover NOTE If you have any unconnected battery connectors on battery cable after installation make sure they are wrapped with electrical tape so that there is no chance of shorting the connector to any metal You can also remove the extra cable connector permanently by cutting ...

Page 4: ...4 24V Battery Configuration Device 1 Device 2 FG Frame Ground Do Not Connect to V GND V There are two V connec tions 1 and 2 12V or 24V V There are two V connections 1 and 2 ...

Page 5: ...of 12V or 24V 5A Max Solar Panel Size 85W Overcharge Protection 14 4V 28 6V Over discharge protection 11V 20V Over discharge recovery voltage 12V 22V Controller Self Consumption 0 5W POE Power Supply 24V 48V 60W Enclosure Type Polycarbonate Enclosure External Size 17 5 x 12 5 x 6 445 x 318x 152mm Enclosure Internal Size 14 x 10 x 5 356 x 254 x 127mm Space for Customer Electronics 3 x 5 x 3 76 x 12...

Page 6: ...on longitude and is different if summer or winter If the panel won t have seasonal adjust ment set for winter angle and leave this setting year round See tycon power com learning_center for additional information If you are plan ning to keep solar panel angle fixed all year then set the angle to Your_Latitude 0 9 30 7 BATTERY HOOKUP Always connect the battery first and discon nect the battery last...

Page 7: ...voltage sent to the devices So 12VDC in and you get 12VDC POE to the devices The operating voltage is 12V to 56VDC Limited Warranty The UPSPro products are supplied with a limited 24 month warranty which covers material and workmanship defects This warranty does not cover the following Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning o...

Page 8: ...8 8000010 Rev 5 UPS PL UPSPro Qwik Install Guide ...