background image

 

 

SPECIFICATIONS  

           

Subject to change without notice

 

 

 

 

Battery Voltage (DC) 

12V or 24V

 

Load Output Voltage (DC) 

11-15VDC / 22-29VDC 

Suggested Max Load 

450W 

AC Input Voltage 

120/240VAC 50/60Hz 5A Max 

Battery Charge Voltage 

14.4V / 28.8V 

Battery Charge Current 

40A / 20A 

Battery Charge Capacity 

600W 

Capacity (Ah) @ 12V 

50Ah to 200Ah

 

Battery Type 

Valve Regulated Sealed Lead 

Acid /  Absorbent Glass Mat (AGM)

 

Battery Life 

5 Years

 

Controller Type 

40A MPPT with status display and 

load control

 

Overcharge Protection 

14.4V / 28.8V

 

Over-discharge protection 

11V / 22V

 

Over-discharge recovery voltage 

12.6V / 25.2V

 

Controller Self Consumption 

<1W

 

Enclosure Type 

Powder Coated Steel

 

Enclosure External Size 

24 x 15 x 14"   

(610 x 381 x 356mm)

 

 

Enclosure Internal Size 

23 x 14 x 12"   

(584 x 356 x 305mm)

 

 

Operating Temperature 

-

30°C to +60°C 

System Weight (without batteries) 

55lb (25kg)

 

 

Battery Weight (each) 

37lb (17kg)

 

 

Summary of Contents for UPSPro UPS-ST-600

Page 1: ...ghts and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet...

Page 2: ...erVent plate STEP 3 Install hole plug in drain hole in bottom right corner of the en closure STEP 4 Mount the DIN rail to the door using screws provided Mount any extra equipment to the orange backplate and secure the backplate in the enclosure Note The DIN rail can also be mounted to the orange back plate or sides of enclosure if desired STEP 5 If pole mounting the enclo sure assemble the pole mo...

Page 3: ...t this cord to hardwire into the mains You can also mount conduit to the enclosure if local codes require it During operation the charger fan may run This is normal STEP 10 Mount any customer electronics to the inside of the enclo sure Connect any loads to the Solar Controller LOAD output LOAD LOAD Press red SET button to turn on off the LOAD output Note There are multiple cable gland feedthrough ...

Page 4: ...4 UPS ST12 50 600 1 Battery UPS ST24 50 600 2 Battery UPS ST24 100 600 4 Battery ...

Page 5: ...ve Regulated Sealed Lead Acid Absorbent Glass Mat AGM Battery Life 5 Years Controller Type 40A MPPT with status display and load control Overcharge Protection 14 4V 28 8V Over discharge protection 11V 22V Over discharge recovery voltage 12 6V 25 2V Controller Self Consumption 1W Enclosure Type Powder Coated Steel Enclosure External Size 24 x 15 x 14 610 x 381 x 356mm Enclosure Internal Size 23 x 1...

Page 6: ...6 ...

Page 7: ...mperature For cold temperatures the capacity is reduced by 20 30 3 VENTING The enclosure is vented thru the included PowerVent The fan is thermostatically controlled to turn on when the temperature inside the enclosure exceeds 45C It runs on 12V to 24VDC 4 DUAL INPUTS The UPS ST 600 can be used with AC Power alone or Solar Power alone or a combination of both 5 SOLAR PANEL The MPPT controller used...

Page 8: ...tery you will re duce the battery life 9 LOAD OUTPUT The LOAD output on the Solar Charge Controller is unregulated What that means is the voltage output follows the battery voltage This is typically 11 15V for a 12V system and 22 29V for a 24V system It is up to the user to make sure the connected load is compati ble with these voltages A voltage regulator can be added to provide regulated output ...

Reviews: