5
STEP 16:
Once you open the web interface, you can set the voltage
for each port including the Aux port and you can turn the power on and
off to each port.
WARNING!
Be careful not to turn on the power to the port that
your network is connected to. If the connected device is not a PoE
compatible device it might be damaged by the PoE power on the
port.
STEP 17:
Refer to the controller user guide for more info on setup and
use of the controller features.
TECH CORNER
Additional Information you may find useful
1. CONTROLLER:
The controller will turn off all loads when the battery
voltage falls below a set value. This value can be set in the user inter-
face. This low voltage disconnect function is needed to preserve the life
of the batteries.
SPECIFICATIONS
Subject to change without notice
UPS
-
STL48
-
50
UPS
-
STL48
-
100
Load Voltage
24V/48V Selectable
24V/48V Selectable
Max Load
200W
200W
VAC Input +/
-
10%
115 / 230VAC user selectable
VAC Input Current
12A @ 115VAC ; 6A @ 230VAC Max
Battery Capacity
200Ah
400Ah
Battery Type
Non
-
Spillable Sealed Lead Acid —AGM
Battery Life
5 Years
5 Years
Over
-
discharge protec-
tion
45.8V to 47.8 –
settable in web interface
Output Ports
Qty 7 Gigabit Passive PoE 24/48V (Qty 3 @
35W and Qty 4 @ 15W)
Aux Output
24V or 48V @ 2.25A Max;
Selectable via Web Interface
Self Consumption
3.5W Typ
3.5W Typ
Enclosure Type
Steel—STL
Steel—STL
Operating Temp
-
30°C to +60°C (
-
22°F to 140°F)
Summary of Contents for UPS-STL48-50
Page 7: ...7 ...