background image

ø

7 hose 

*Connect with

 the Scale Remover

*Alkaline outlet pipe, Drain outlet pipe

5/16″- 7/16″

gender

Connect

ø

10 Gender

Combined hose

B. How to use for the Undersink model

If the connection location of 

,

 is different, it may cause product malfunctions.

How to store after use

Product Warranty

If citric acid or scale substance remain in the Scale Remover 

after use, it may cause malfunctions. Be sure to remove 

the citric acid and scale substance thorough before storing.

A. How to use for the desktop model

C. How to use for the Hybrid model 

(Hybrid water ionizer)

D. How to use connector

Place the scale remover in the place to be used, and cut the connecting 

hose to an appropriate size.

The connecting hose must be connected to different locations, each of 

 

and 

, respectively, so cut the hose to the appropriate size before use.

This applies only to the initial operation. Please store the cut hose and use 

it when operating the scale remover.

Connect water ionizer’s alkaline outlet and Scale Remover’s outlet connection 

with the connecting hose. 

(Refer to 

)

Connect water ionizer’s drain and Scale Remover’s inlet connection with 

the connecting hose. 

(Refer to 

)

Put 

500ml

 of water into the Scale Remover, add 

2 bags

 of the citric acid 

included as a component, and stir until the citric acid is completely dissolved.

Check the connection hose between water ionizer and Scale Remover 

again, and press the button of the Scale Remover to start the operation 

(the operation LED light turns on while operating).

The Scale Remover operates for approximately 10 minutes and automatically 

turns off. 

For high hardness areas, operate twice in a row.

After the operation is completed, disconnect the connecting hose from 

the water ionizer and the Scale Remover.

To remove the residual cleaning liquid inside the water ionizer, press the 

“Purified water” button and let the water out for about 3 minutes.

After  washing  the  Scale  Remover  inside  and  hose,  please  put  all 

components in Scale remover and store the device safety.

After using the Scale Remover, remove the inlet hose and filter, clean 

them separately, and dry them before storing.

Attach the hose with the Scale Remover’s outlet connection.

Wash the Scale Remover’s inside with clean water and put 500ml of water.  

DO NOT add citric acid.

Press the button to completely drain the Scale Remover’s inside water

and press the button again to stop the device.

Dry the device and the outlet hose completely, and store.

Inlet

 

Outlet 

Alkaline outlet 

Drain 

Inlet

 

Outlet 

Alkaline outlet 

Drain 

When using for UCE-PLUS 

model, connect the gender 

combined hose (2EA) with 

the  water  ionzer’s  outlet 

pipe and connect with the 

Scale Remover.


Attach hose with

outlet connection

Adjust the position to

make “discharge water”

flow to the sink

Wash inside

and

add water

 Press the button

to clean the inside

Refer to 

Power supply

Battery replacement cycle

Operating time

Battery replacement (AA x 3ea)  

*Separately sold item

                 approximately 10 times when operating for 10 min

10 minutes / 1 time operation

Dimension(mm)  

W118.5 * D101 * H179

Weight   

 360g

Product Name

Product Model

Date of Purchase

TYENT Scale Remover

YT25-SR

Warranty Period

One Year from the

Date of Purchase

[12months]

If the connection location of 

,

 is different, it may cause product malfunctions.

The Hybrid water ionizer should be turned on before using 

the scale remover. Check the power plug before using.

①~④ 

Pease refer to how to use the Scale remover on top counter water ionizer.

Press the SET button of the water ionizer for 3 seconds to enter the 

setting mode, and press the RTR button for 3 seconds in the setting 

mode to run the scale cleaning mode. (2 beeps)

The device will automatically operate for 10 minutes, and the screen 

will display twice for 5 minutes each.

Make sure to operate the Scale Remover after entering RTR mode. 

(risk of leakage)

After  checking  the  water  ionizer’s  scale  cleaning  mode,  press  the 

button on the Scale Remover to start the operation (the operation LED 

light turns on while operating).

The Scale Remover and the scale cleaning mode operate for approximately 

10 minutes and automatically turns off.

Press the SET button for 3 seconds to return to stand by screen.

For high hardness areas, operate twice in a row.

(

Refer to 

~

)

After the operation is completed, disconnect the connecting hose from

the Hybrid water ionizer and the Scale Remover.

To remove the residual cleaning liquid inside the water ionizer, press the

“Purified water” button and let the water out for about 3 minutes.

After  washing  the  Scale  Remover  inside  and  hose,  please  put  all

components in Scale remover and store the device safety.

*If connecting with the Drain hose

directly (without Darin Faucet)

When connecting the Scale Remover’s inlet connection and the water 

ionizer’s Drain outlet, and when connecting the directly with Drain hose 

without a separate drain faucet, you must use the connector to connect. 

Please refer to the draft below

ø

6 Drain hose

How to connect 2 hoses with the connector

1/4″- 3/8″

*Connect Water Ionizer Drain outlet

ø

7 hose 

*Connect with

 the Scale Remover

When storing, be careful not to lose the filter inside 

of the product. If the filter is lost or contaminated, 

replace the filter(included as the components).

Place the scale remover in the place to be used, and cut the connecting 

hose to an appropriate size.

The connecting hose must be connected to different locations, each of 

 

and 

, respectively, so cut the hose to the appropriate size before use.

This applies only to the initial operation. Please store the cut hose and use 

it when operating the scale remover.

Connect water ionizer’s alkaline outlet and Scale Remover’s outlet connection 

with the connecting hose. 

(Refer to 

)

Connect water ionizer’s drain and Scale Remover’s inlet connection with 

the connecting hose. 

(Refer to 

)

Put 

500ml

 of water into the Scale Remover, add 

2 bags

 of the citric acid 

included as a component, and stir until the citric acid is completely dissolved.

Check the connection hose between water ionizer and Scale Remover 

again, and press the button of the Scale Remover to start the operation 

(the operation LED light turns on while operating).

The Scale Remover operates for approximately 10 minutes and automatically 

turns off. 

For high hardness areas, operate twice in a row.

After the operation is completed, disconnect the connecting hose from 

the water ionizer and the Scale Remover.

To remove the residual cleaning liquid inside the water ionizer, press the 

“Purified water” button and let the water out for about 3 minutes.

After  washing  the  Scale  Remover  inside  and  hose,  please  put  all 

components in Scale remover and store the device safety.