L A S E R S F O R M A R K I N G
Operator Pendant
System Power - Turns on power to the Zetalase.
Laser Enable - Left is Off. Right is On. Should you wish to protect the system
from unauthorized operation, simply remove the “Laser Enable Key” and store in
a safe location when not in use.
Auto/Manual Switch - Manual is Left. Auto is Right. Auto mode will fire the laser
automatically when the door is shut and the Shutter is OPEN. Manual Mode
requires Shutter OPEN and physical “Start” button pressed or software start.
Interior Lamp - Turns ON/OFF the interior lamp inside the Zetalase.
Emergency Stop - Will disable the laser and any moving axis.
Zetalase™ Status Indication
Green Laser Ready
Yellow Laser Busy
Marking Complete
System Fault
Shutter - Push Open/Close. Shutter is open when pressed and doors are closed
with safety interlocks engaged.
Start/Stop - Starting or stopping the laser process in Manual mode.
Axis Control - On standard Zetalase models this will move laser Z-Axis UP/Down.
On optional Automatic Z-Axis models this is an overtravel bypass button.
USB Ports - Provides access to embedded PC for transfer of files VIA removeable
USB media or connection of peripheral equipment (Barcode Scanners, Mouse,
Keyboard)
- LED is illuminated when the software is ready
- LED is illuminated when laser process is busy
- LED is illuminated when marking is complete
- LED is illuminated with an Emergency Stop
or Blinking with Interlock Error
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
Zetalase
™
19
General Manual SE 1