SVENSKA
Beskrivning av modularkontakt
Inkoppling av komponenter i modularkontakter (max. kabelarea till RJ10: 0,9mm/ 0,2mm², AWG24)
Enhet
Pos
Pin
Anmärkning
Tempsensor (10kΩ)
1
2-3
Skall vara av modell NTC. Kan även kopplas in på Pos. 4.
Externbrytare utan LED-indikering
2
3-4
Både konstant- eller impulsslutning fungerar.
Externbrytare med LED-indikering
2
2-3-4
12VDC (max 40mA). Tylö externbrytare artikelnr: 9090 8045
Dörrkontakt utan larm för dörrstatus
3
3-4
Av modell NO (Normally Open). Tylö dörrkontakt artikelnr: 9090 8035.
Dörrkontakt med larm för dörrstatus
3
2-3-4
12VDC (max 40mA)
1. NTC Sensor (RJ10)
2. Externbrytare (RJ10)
3. Dörrkontakt (RJ10)
4. SEC/NTC Sensor (tillval) (RJ10)
5. Addon (tillval)(RJ45)
6. RS485 manöverpaneler (RJ10)
7. RS485 manöverpaneler (RJ10)
8. RS485 manöverpaneler (RJ10)
9. RS485 manöverpaneler (RJ10)
10. Modularplugg (RJ10)
11. Modularkontakt (RJ10)
1
2
3
4
Pin:
Pos 1.
NTC
Pin 1:
Pin 2: NTC
Pin 3: NTC
Pin 4:
Pos 2.
Ext sw
Pin 1:
Pin 2: LED
Pin 3: SW
Pin 4: 12 V
Pos 6-9.
4x RS485
Pin 1: A
Pin 2: B
Pin 3: 12 V
Pin 4: GND
Pos 3.
Door sw
Pin 1:
Pin 2: LED
Pin 3: SW
Pin 4: 12 V
Pos 4.
Bim/NTC
Pin 1: Bim
Pin 2: NTC
Pin 3: NTC
Pin 4: Bim
Pos 5.
Addon (option)
1
2
3
4
Pin:
10
11
1
2
6
7
8
9
3
4
5
ENGLISH
Modular connector description
Connecting components to the modular contacts (maximum cable cross-sectional area for RJ10. 0.9mm/ 0.2mm², AWG24)
Unit
Pos
Pin
Comment
Temp.sensor (10kΩ)
1
2-3
Must be NTC type. May also be connected at Position 4.
External switch without LED indication
2
3-4
Both constant and impulse deactivation work.
External switch with LED indication
2
2-3-4
12VDC (maximum 40mA). Tylö external switch, item number: 9090 8045
Door contact without alarm for door status
3
3-4
Of type NO (Normally Open). Tylö door contact, Item No.: 9090 8035.
Door contact with alarm for door status
3
2-3-4
12VDC (max. 40mA)
1. NTC Sensor (RJ10)
2. External switch (RJ10)
3. Door contact (RJ10)
4. SEC/NTC Sensor (option) (RJ10)
5. Addon (option)(RJ45)
6. RS485 control panels (RJ10)
7. RS485 control panels (RJ10)
8. RS485 control panels (RJ10)
9. RS485 control panels (RJ10)
10. Modular plug (RJ10)
11. Modular contact (RJ10)
1
2
3
4
Pin:
Pos 1.
NTC
Pin 1:
Pin 2: NTC
Pin 3: NTC
Pin 4:
Pos 2.
Ext sw
Pin 1:
Pin 2: LED
Pin 3: SW
Pin 4: 12 V
Pos 6-9.
4x RS485
Pin 1: A
Pin 2: B
Pin 3: 12 V
Pin 4: GND
Pos 3.
Door sw
Pin 1:
Pin 2: LED
Pin 3: SW
Pin 4: 12 V
Pos 4.
Bim/NTC
Pin 1: Bim
Pin 2: NTC
Pin 3: NTC
Pin 4: Bim
Pos 5.
Addon (option)
1
2
3
4
Pin:
10
11
1
2
6
7
8
9
3
4
5