TYM 1000/2000 Slide Gate Operator Installation Guide
- 29 -
Rev 9 02/14
Operation Indications
During normal operation, the Controller’s displays will
indicate current operating conditions and status.
Power-up Display
When the Controller powers up, dashes will show on the
display for one second, then the firmware version number
will be displayed for one second.
Idle Condition
While the Controller is idling, waiting for a command, the
display will show circulating dashes.
Last Gate Position/Condition
When the gate moves or stops, the display will show the
status for up to one minute.
• Stop is displayed as
St
• Full Close is displayed as
FC
• Full Open is displayed as
FO
• Entrapment is displayed as
En
Pre-start Delay
During the pre-start delay, the display will countdown the
number of seconds remaining before the operator starts.
Reverse Delay
If the gate travel direction is reversed from a user activation
or reversing device, and a reverse delay is set, the display
will count down the delay time in seconds before the
operator restarts.
Run Timer
While the gate is opening or closing, the number of seconds
running time is displayed.
Error Indications
During abnormal operation, the Controller’s displays and
beeper will indicate the error condition that has occurred.
Entrapment or Obstruction Reset
If an entrapment condition occurs detected by two repeated
open or close obstruction triggers, the Controller will lock
the operator out. The beeper will sound constantly and the
gate will not operate. To reset the Controller press the
STOP
button or press the
RESET
button on the operator’s cover.
COMM LINK Connection Failure
In dual gate installations, if there is a connection failure
between the two operators, the
COMM LINK
indicator will
blink once a second. During this condition the gate will not
operate, except if triggered by the
FIRE DEPT
input, which
functions normally.
MGT Obstacle Transmitter Trouble
If any MGT transmitters are used with the operator, their
supervision feature will alert the Controller if there is any
trouble with the transmitter. MGT transmitters send hourly
status reports and will send low battery reports when the
transmitter has a low battery. The MGT transmitters also
have a tamper detection switch that will trigger when their
case is opened.
When the Controller detects a low transmitter battery, a
tamper signal, or missing transmitter status reports, the
gate will still operate normally, but the beeper will change
as follows:
• The Pre-start Alarm will beep twice as fast.
• The Run Alarm will beep twice as fast and continue for five minutes
after the gate stops.
• The sounder will “chirp” every five seconds when the gate is idle.
Correct the trouble (close case, replace battery, or replace
transmitter) to clear the obstacle transmitter trouble
indications.
Maximum Run Time Exceeded
If the Maximum Run Time is exceeded, the Controller stops
the operator the same as if a double obstacle has occurred
in an entrapment condition. The entrapment alarm sounds
constantly, and is cleared by pressing the
STOP
button or the
RESET
button on the cover. After the
STOP
or
RESET
button
is pressed, because the Maximum Run Time has been
exceeded, the sounder will beep twice every five seconds.
The next operation of the gate will clear the indication.
CONTROLLER ERROR CAUSES AND INDICATIONS
ERROR CAUSE
ERROR INDICATION
HOW TO CLEAR
TWO SAFETY REVERSALS (ON
SINGLE GATE OR ON EITHER
DUAL GATE)
En 00
, CONTINUOUS ALARM
BEEPER, GATE DISABLED
PRESS STOP BUTTON
MAXIMUM RUN TIMER
EXCEEDED ON OPENING
En 01
, AND MAX RUN LED,
CONTINUOUS ALARM BEEPER,
GATE DISABLED
PRESS STOP BUTTON,
CLEARS CONTINUOUS ALARM,
THEN DOUBLE BEEP EVERY
5 SECONDS UNTIL NEXT
OPERATION
MAXIMUM RUN TIMER
EXCEEDED ON CLOSING
En 02
, AND MAX RUN LED,
CONTINUOUS ALARM BEEPER,
GATE DISABLED
PRESS STOP BUTTON,
CLEARS CONTINUOUS ALARM,
THEN DOUBLE BEEP EVERY
5 SECONDS UNTIL NEXT
OPERATION
COMM LINK FAILURE
En 03
, AND COMM LINK LED,
CONTINUOUS ALARM BEEPER
FOR 1 MINUTE, GATE DISABLED
(EXCEPT FOR FIRE DEPT INPUT)
PRESS STOP BUTTON, CLEARS
CONTINUOUS ALARM
GATE FULL OPEN RESULTING
FROM FIRE DEPT INPUT
En 04
, GATE DISABLED
PRESS STOP BUTTON
FAIL SAFE OR FAIL SECURE
BECAUSE OF BATTERY
VOLTAGE DROP BELOW 21.6
VDC DUE TO AC POWER LOSS
En 05
, GATE DISABLED
BATTERY VOLTAGE MUST RISE
ABOVE 24 VDC
OTHER CONTROLLER IN
ENTRAPMENT (DUAL GATE)
En 06
, GATE DISABLED
CLEAR ENTRAPMENT ON
OTHER CONTROLLER (PRESS
STOP)
LOW AC VOLTAGE AT
CONTROLLER
En 07
, GATE DISABLED
LOW VOLTAGE AC POWER MUST
RISE ABOVE 20 VAC
INPUT TRIGGERED DURING
ENTRAPMENT LOCKOUT
En 08
, GATE DISABLED
PRESS STOP BUTTON
COMPATIBILITY PROBLEM
En 09
, GATE DISABLED
UPDATE FIRMWARE AND RESET
BOTH PAIRED CONTROLLERS
EEPROM PROBLEM
En 10
, GATE DISABLED
TRY RESET, CALL TECH. SUPPORT
DC MOTOR MISMATCH
En 11
, GATE DISABLED
REPROGRAM MOTOR TYPE OR
CHANGE DC MOTOR BOARD,
NEXT GATE MOVEMENT WILL
RETRY DC MOTOR CHECK
MOTOR FAILURE
En 12
, GATE DISABLED
REPLACE MOTOR
AC POWER LOSS IN OPEN
IMMEDIATE POWER FAIL MODE
En 13
REAPPLY AC POWER
MAXIMUM RUN TIMER
EXCEEDED AFTER AC POWER
LOSS
En 14
BATTERY VOLTAGE MUST RISE
ABOVE 24 VOLTS
MGT SUPERVISORY CONDITION
(TAMPER, LOW BATTERY,
MISSING HOURLY STATUS)
FAST BEEPS DURING PRESTART,
FAST BEEP RUN ALARM, CHIRP
EVERY 5 SECONDS AT IDLE
CLEARS WHEN MGT CONDITION
CLEARS
WARNING
The Stop and/or Reset button must be located in the
line-of-sight of the gate. Activation of the reset control
shall not cause the operator to start.