background image

 

 

Doc

 

No.

 

FM0600

  

issue

 

E

   

Page

 

5

 

 

9.

 

QUICK

 

SETUP

 

MODE

 ‐ 

CONTINUED

 

 

Repeat

 

as

 

above

 

to

 

set

 

the

 

Stop

 

Time

 

then

 

press

 

the

 

ENTER

 

key

 

 

the

 

display

 

will

 

change

 

to

 

Another

 

Time

 

Slot

 

?

  

No

  

Use

 

the

 

S

 

key

 

to

 

select

 

Yes

 

to

 

enter

 

more

 

time

 

slots

 

or

 

press

 

the

 

ENTER

 

key.

 

The

 

display

 

will

 

go

 

back

 

to

 

the

 

set

 

on/off

 

times

 

menu,

 

press

 

the

 

X

 

key

 

to

 

move

 

to

 

the

 

next

 

option;

 

 

Would  you  like  an 

 

W

 

instant  alarm ? 

  

X

 

 

 

 

         

yes = enter, next = 

W

 

X

 

 

Press

 

the

 

ENTER

 

key

 

and

 

the

 

display

 

will

 

change

 

to

  

Instant

 

Alarm

 

?

  

No

 

Use

 

the

 

ST

 

keys

 

to

 

choose

 

Yes

 

or

 

No

 

then

 

press

 

ENTER

.

 

If

 

you

 

choose

 

Yes

 

an

 

alarm

 

will

 

be

 

sent

 

immediately

 

the

 

person

 

leaves

 

their

 

bed/chair.

 

The

 

display

 

will

 

go

 

back

 

to

 

the

 

instant

 

alarm

 

menu,

 

press

 

the

 

X

 

key

 

to

 

move

 

to

 

the

 

next

 

option;

 

 

Would you like a delay 

 

W

 

before an alarm ? 

  

X

 

 

 

 

         

yes = enter, next = 

W

 

X

 

 

Press

 

the

 

ENTER

 

key

 

and

 

the

 

display

 

will

 

change

 

to

  

Enter

 

Time

 

Delay;

 

00

 

Mins

 

Use

 

the

 

ST

 

keys

 

to

 

set

 

the

 

delay

 

before

 

an

 

alarm

 

from

  

1

 

to

 

99

 

Minutes

 

then

 

press

 

the

 

ENTER

 

key.

 

The

 

display

 

will

 

go

 

back

 

to

 

the

 

delay

 

before

 

alarm

 

menu,

 

press

 

the

 

X

 

key

 

to

 

move

 

to

 

the

 

next

 

option;

  

 

Would  you  like  a 

 

W

 

NOT  IN  BED  alarm ? 

  

X

 

 

 

 

         

yes = enter, next = 

W

 

X

 

 

Press

 

the

 

ENTER

 

key

 

and

 

the

 

display

 

will

 

change

 

to

  

Not

 

in

 

Bed

 

Alarm;

  

No

 

Use

 

the

 

ST

 

keys

 

to

 

choose

 

Yes

 

or

 

No

 

then

 

press

 

ENTER

.

 

If

 

you

 

choose

 

No

 

the

 

monitoring

 

will

 

start

 

when

 

the

 

person

 

is

 

detected

 

in

 

bed.

 

If

 

you

 

choose

 

Yes

 

the

 

display

 

will

 

change

 

to

  

Not

 

in

 

Bed

 

Alarm;

  

How

 

Long

 

?

  

000

 

Mins

 

Use

 

the

 

ST

 

keys

 

to

 

set

 

the

 

not

 

in

 

bed

 

alarm

 

from

 

0

 

to

 

999

 

minutes

 

then

 

press

 

the

 

ENTER

 

key

 

(an

 

alarm

 

will

 

be

 

sent

 

if

 

the

 

person

 

is

 

not

 

in

 

bed

 

after

 

this

 

period).

 

The

 

display

 

will

 

go

 

back

 

to

 

the

 

not

 

in

 

bed

 

alarm

 

menu,

 

press

 

the

 

X

 

key

 

to

 

move

 

to

 

the

 

next

 

option;

 

 

Would  you  like  a 

 

W

 

STILL  IN  BED  alarm ? 

  

X

 

 

 

 

         

yes = enter, next = 

W

 

X

 

 

Press

 

the

 

ENTER

 

key

 

and

 

the

 

display

 

will

 

change

 

to

  

Still

 

in

 

Bed

 

Alarm;

  

No

 

Use

 

the

 

ST

 

keys

 

to

 

choose

 

Yes

 

or

 

No

 

then

 

press

 

ENTER

.

 

If

 

you

 

choose

 

No

 

the

 

monitoring

 

will

 

end

 

at

 

the

 

end

 

of

 

the

 

monitoring

 

period.

 

 
 

If

 

you

 

choose

 

Yes

,

 

the

 

display

 

will

 

change

 

to

  

Still

 

in

 

Bed

 

Alarm;

  

How

 

Long

 

?

  

000

 

Mins

 

Use

 

the

 

ST

 

keys

 

to

 

set

 

the

 

still

 

in

 

bed

 

alarm

 

from

 

0

 

to

 

999

 

minutes

 

then

 

press

 

the

 

ENTER

 

key

 

(an

 

alarm

 

will

 

be

 

sent

 

if

 

the

 

person

 

is

 

still

 

in

 

bed

 

after

 

this

 

period).

 

The

 

display

 

will

 

go

 

back

 

to

 

the

 

still

 

in

 

bed

 

alarm

 

menu,

 

press

 

the

 

X

 

key

 

to

 

move

 

to

 

the

 

next

 

option;

 

 

Would  you  like  to 

 

W

 

calibrate  sensor ? 

  

X

 

 

 

 

         

yes = enter, next = 

W

 

X

 

 

Press

 

the

 

ENTER

 

key

 

and

 

the

 

display

 

will

 

change

 

to

 

Put

 

Sensor

 

Under

 

Mattress/Chair

 

 

Press

 

ENTER

 

When

 

Ready

 

Place

 

the

 

sensor

 

under

 

the

 

mattress

 

or

 

chair

 

cushion

 

then

 

press

 

the

 

ENTER

 

key.

 

The

 

display

 

will

 

show

 

30

 

Secs

 

Left

  

…PLEASE

 

WAIT…

 

and

 

count

 

down

 

to

 

zero

 

while

 

the

 

sensor

 

is

 

being

 

calibrated.

 

The

 

display

 

will

 

go

 

back

 

to

 

the

 

calibrate

 

sensor

 

menu,

 

press

 

the

 

X

 

key

 

to

 

move

 

to

 

the

 

next

 

option;

 

 

Would  you  like  to 

 

W

 

go  into  test  mode ? 

  

X

 

 

 

 

         

yes = enter, next = 

W

 

X

 

 

Press

 

the

 

ENTER

 

key

 

and

 

the

 

display

 

will

 

change

 

to;

 

 

Test Mode 

 

 

 

…….. No Client …….. 

  

  

 

W

 

exit

 

 

Get

 

the

 

client

 

to

 

lie

 

on

 

the

 

bed/sit

 

in

 

the

 

chair

 

and

 

the

 

display

 

should

 

show

 

…..

 

Client

 

Detected…..

 

Remain

 

on

 

the

 

bed/chair

 

for

 

10

 

seconds

 

and

 

the

 

display

 

will

 

show

 

Unit

 

is

 

sending

 

status

 

IN

 

code

 

After

 

a

 

short

 

delay

 

(when

 

the

 

IN

 

status

 

is

 

being

 

transmitted)

 

the

 

display

 

should

 

show

 

…..

 

Client

 

Logged

 

IN…..

 

Get

 

the

 

client

 

off

 

the

 

bed/out

 

the

 

chair

 

and

 

the

 

display

 

will

 

show

 

Unit

 

is

 

sending

 

status

 

OUT

 

code

 

After

 

a

 

short

 

delay

 

(when

 

the

 

OUT

 

status

 

is

 

being

 

transmitted)

 

the

 

display

 

should

 

show

 

…..

 

Client

 

OUT…..

 

After

 

10

 

seconds

 

the

 

unit

 

will

 

start

 

to

 

beep

 

and

 

the

 

display

 

will

 

show

 

…..

 

Alarm…..

 

After

 

a

 

further

 

10

 

seconds

 

and

 

the

 

display

 

will

 

show

 

Unit

 

is

 

sending

 

ALARM

 

code

 

End

 

of

 

Test

 

Mode.

 

 

Note:

 

if

 

the

 

client

 

is

 

not

 

detected

 

as

 

in

 

the

 

bed/chair

 

then

 

you

 

may

 

need

 

to

 

adjust

 

the

 

sensitivity

 

 

go

 

to

 

the

 

Advanced

 

Setup

 

t

 

Calibrate

 

and

 

Test

  

t

 

Change

 

Sensitivity

 

option.

  

See

 

page

 

9.

  

 

The

 

display

 

will

 

go

 

back

 

to

 

the

 

test

 

mode

 

menu,

 

press

 

the

 

X

 

key

 

to

 

move

 

to

 

the

 

next

 

option;

 

 
 

 

 
 

 

 
 

 

Summary of Contents for Altec 169MHz

Page 1: ...o their bed chair If the person does not return and an alarm is raised but they are OK then an optional 1 to 99 minute programmable reset period can be set If the person is not detected back in their...

Page 2: ...er includes a power lead and a rechargeable battery depending on the package chosen either a bed sensor a chair sensor a pressure mat or a door contact will also be supplied 1 The sensor controller sh...

Page 3: ...azard Plug the lead into the Sensor Controller Chair Sensor with 2m Lead Tynetec P No ZCS859 Dimensions 325mm x 130mm x 10mm LxWxD RJ45 Double Adapter used to connect 2 chair sensors Tynetec P No P102...

Page 4: ...rrows can be selected with the ENTER key This will either take you to another sub menu or give you the option to change settings Use the ST keys to increase decrease the setting highlighted by the cur...

Page 5: ...o choose Yes or No then press ENTER If you choose No the monitoring will end at the end of the monitoring period If you choose Yes the display will change to Still in Bed Alarm How Long 000 Mins Use t...

Page 6: ...e and Test d Calibrate Sensor View In Out States Change Sensitivity Calibrate and Test c Test Mode Exit Calibrate Sensor place the bed chair sensor in position and press ENTER to learn the un occupied...

Page 7: ...ensor On all the time No Active start stop time periods all 00 00 disabled Instant alarm Yes Delay before Alarm No Not in Bed Alarm No Still in Bed Alarm No Low Battery Beep Yes Radiplugs disabled X10...

Page 8: ...ach announces Trigger Radio Device and the front light starts flashing GREEN 2 Press the CARER CALL button the Reach will announce the Sensor Type 3 Press the GREEN button to exit the learn mode 4 Che...

Page 9: ...d to send a CARER CALL Press this key once and the display will show Unit is sending a CARER CALL alarm PLEASE WAIT After about 10 seconds the display will blank You will hear reassurance tones from t...

Reviews: