background image

7.6.1 Device Management:

1. Configuration file:You can view the configuration file saved in "Configure".

2. Remember the device access key:

Don’t turn on the switch: enter the access key every time you connect the device

Turn on the switch: when connection the device, you only need to input the

access key once (default: remember the key)

3. The firmware update:

Don’t turn on the switch: Firmware upgrades are not allowed

Turn on the switch: After connection, there is firmware upgrade function(default)

7.6.2 Time&Time zone Setting(Only for generating reports through the APP):

1. System default/Time Zone:

Don’t turn on the switch: is UTC time zone or another time zone as you choose

Turn on the switch:is the current time zone of the system (default: system

default)

2. Data Format: MM/DD/YY HH:MM:SS(default) or DD/MM/YY HH:MM:SS

7.6.3 Report settings(Only for generating reports through the APP):

1. Include Tabular Data in PDF: Select include or exclude (default: include).

2. Include Tabular Data in CSV: Select include or exclude (default: include).

Summary of Contents for TZ-BT05B

Page 1: ...TZ BT05B User Manual V1 7...

Page 2: ...es experimental test rooms museums and other temperature testing 2 Applications 1 Refrigerated storage and transportation 2 Archives 3 Experimental test rooms 4 Workshop 5 Museums 6 Pharmaceutical env...

Page 3: ...60 Temperature detecting range 40 80 Just for the temperature sensor Temperature detecting accuracy 0 5 20 40 1 Other temperature 5 Caution 1 Being close to a metal object will interfere with the sig...

Page 4: ...oth of the mobile devices and do the settings data transmission recording synchronization send to email Apply the Bluetooth BLE way so you can use Android phone for temperature monitoring Client can d...

Page 5: ...7 2 2 Enter the device connection page and click Connect After a successful connection the device ID will be displayed on the Devices page indicating that the device has been registered successfully...

Page 6: ...the menu function and click device to enter the multidevice interface The functions of the device interface are as follow 7 2 1 To view device information The name ID MAC temperature data model and s...

Page 7: ...Status description of the device in different symbols Temperature normal Temperature alarm including both high and low temperatures 7 2 2 Delete the device Long press to delete the device...

Page 8: ...arm When the device exceeds the preset upper or lower limit the alarm information will be displayed and the alarm bell will ring Clicking CLOSE to turn off the alarm information and alarm bell 7 3 Dev...

Page 9: ...t mode of the device will be displayed Four buttons will be displayed at the bottom of the interface Note The device will not update the data in the connection process By default the device will be di...

Page 10: ...Note The smartphone must have a mailbox APP and login account to send email B Chart...

Page 11: ...C List 7 4 Configure device After connection when the device does not start recording you can click Configure to set the device...

Page 12: ...changes with the logging interval 7 4 3 Advanced settings A Access key Must be enable default 000000 7 4 4 Alarms A Low temperature limit 25 B High temperature limit 60 7 4 5 Description You can set...

Page 13: ...ding 7 5 2 Chart report comparison supporting up to 5 files Check the data file and click Comparison to compare the temperature chart reports of different data files 7 5 3 Delete data file Check the d...

Page 14: ...Turn on the switch After connection there is firmware upgrade function default 7 6 2 Time Time zone Setting Only for generating reports through the APP 1 System default Time Zone Don t turn on the swi...

Reviews: