B.1.3 RF trace specification
The 50
Ω
coplanar micro-strip dimensions used in these reference designs are stated in Figure 19 and
Figure 19: Coplanar micro-strip dimension specification
Item
Value
S
300 µm
W
540 µm
T
35 µm
H
300 µm
ε
r
4
Table 33: Coplanar micro-strip specification
B.1.4 Mechanical dimensions
The mechanical dimensions and position of the components are specified in
The solid GND layer beneath the ‘top layer’ shall be minimum 19x15 mm according Figure 20. No
traces are allowed to be routed on the GND layer within this area but vias and small openings are
allowed.
The minimum size of the top layer GND plane is marked in Figure 20 and no other components are
allowed within this area.
Figure 20: Mechanical dimensions of EVK-LILY-W131