The Customer should anticipate that the average 

life span of the pump and fan, under normal condi-

tions, is 2 years of continuous use. 

The Customer also acknowledges that the pump 

and fan may be subject to premature wear and tear 

when used in very dirty environments, in which case 

in the presence of aggressive contaminants, the 

Customer must consider the possibility of prematu-

re deterioration of the components and conse-

quently anticipate their replacement.  

15.4.4. U-Ox additive

U-Ox additive will only be sold in conjunction with 

the AIRcel70 unit. The bottles must be stored in their 

original packaging and must not be exposed to a 

temperature higher than 30°C or lower than 0°C. 

The bottles must not be opened before use and 

their contents must never be placed in a different 

container in case the bottle is damaged. 

The single 

dose supplied must be well shaken before use 

and used in full, every 30 days.

 Failure to add the 

U-Ox additive every 30 days will result in a loss of 

system performance and void the performance warranty. 

An unpleasant "algae" odor perceived immediately 

after opening the bottle is normal and is due to a 

limited release of gas from the biological consortium 

as a result of possible exposure to different tempe-

ratures. This is not a sign of deterioration of the 

compound and will not adversely affect AIRcel70's 

performance. U-Ox is intended to be used exclusively 

as an additive for AIRcel70 bioreactors. 

U-Ox has a shelf life of 3 years. 

15.4.5. Return/Refund

AIRcel70 units can be refunded or returned in case 

of malfunction at first installation or defective com-

ponents. 

If a unit is damaged during transport, it cannot be 

refunded. The Customer is strongly advised to 

insure transportation for the full value of the item.

If the end user has used the unit improperly, U-Earth 

is not responsible for a refund. 

a.

 If any unit has manufacturing defects, having 

been used in accordance with the performance 

warranty clauses, it will be U-Earth's responsibility to 

repair, re-manufacture or replace, at its discretion, 

said units recognizing an EXW price to which a 

discount will be applied in proportion to the unfulfilled 

life during the warranty period, excluding any 

customs, taxes, labor for replacement.

b.

 U-Earth's liability will apply as long as the total 

number of items supplied for replacement is less 

than or equal to the initial number of items installed. 

Claims for damages, as well as any right of appeal 

are excluded. 

c. 

Transportation of units to be returned to U-Earth 

for warranty compliance verification shall be prepaid 

by Customer. If the verification fails, i.e. the warranty 

clauses are not respected, the Customer shall pay 

all expenses incurred by U-Earth personnel for the 

investigations performed. If the malfunction is not 

found by U-Earth, U-Earth will return the goods to 

the Customer, with transport paid for by the reci-

pient. 

15.4.6. Disclaimer of Liability

No warranty, either express or implied, is warranted 

beyond what is expressly stated above.

Implied warranties of merchantability and fitness for 

a particular purpose are not given and are expressly 

excluded. 

U-Earth shall not be liable for indirect, incidental, puni-

tive or exemplary damages, lost profits, downtime of 

facilities, or suits by third parties against the Customer, 

due to component malfunctions or defects. These 

terms and conditions are subject to change.

15.4.7. Storage Conditions

The device is intended to be stored under the 

following environmental conditions:

15

Summary of Contents for AIRcel70

Page 1: ...AIRcel70 INSTRUCTIONS FOR USE ...

Page 2: ... United Kingdom VAT GB311666618 PEC u earthbiotech legalmail it Registered office in Italy U Earth Biotech Ltd Via Matteo Bandello 16 20123 Milan Italy C F 95209340108 P IVA 10920970968 More info on www u earth eu Contact service u earth eu Rev 22 September 2021 01 ...

Page 3: ...ntribution to the environment 5 Disposing of your device at the end of its useful life 6 Safety instructions 7 Intended Use 8 Technical safety 9 Components 10 What s in the box 11 Using the AIRcel70 12 Periodic cleaning procedure 13 Correct use 14 U Ox Material Safety Data Sheet MSDS 15 AIRcel70 Warranty Conditions 16 Declaration of conformity ...

Page 4: ... can make up more than 98 of the total particulate matter These particles are the most harmful to humans as they can penetrate as far as the pulmonary alveoli U Earth is currently the most efficient system in the sector as it is able to capture the pollutants measured at the site in question by biodegrading the molecules unlike other technologies on the market that act only on certain pollutants A...

Page 5: ...AIRcel70 Do not allow children to play with the AIRcel70 put their hands in the fan or tip it over 4 Keep packaging film out of reach of children because of choking hazard 4 Your contribution to the environment Disposal of transport packaging The packaging protects AIRcel70 from damage during transport The packaging material is chosen from envi ronmentally friendly and disposable materials which m...

Page 6: ...fety of AIRcel70 is only guaranteed when it is connected to an electrical system that com plies with safety regulations It is very important that you check the essential safety requirements and if in doubt have an experienced electrician examine your electrical system Connect the device only to legally compliant systems 3 For safety reasons do not use extension cords fire hazard due to overheating...

Page 7: ...ply cable input voltage 100 240 Volt approx frequency 50 60 Hz 3 Pure Air Zone adhesive 4 Instructions for use 11 Using the AIRcel70 11 1 Installation To proceed with the installation of AIRcel70 follow the procedure described below 1 Installation operations must take place with no power supply 2 Remove the AIRcel70 from the box and store it in a suitable place or where indicated by your Air Quali...

Page 8: ...k filter from the tank 5c Remove the protections from the bottom of the BioStack filter these protections prevent damage to the pump during transport 5d Replace the BioStack filter in the tank 6 Add water to the center of the BioStack until it reaches the maximum level indicated on the metal plate Water should be poured through clean con tainers used only for water not previously used to hold othe...

Page 9: ...reating a Pure Air Zone Water evaporates during the bioxidation pro cess and must be supplied regularly You can choose to add a little water each day or a larger amount of water at regular intervals by following Step 3 through Step 9 skipping Step 7 NOTE To add small amounts of water you do not need to unscrew the connector and remove the cover completely just move the cover and lay it on its side...

Page 10: ...ithin a range that protects against all types of pollutants regard less of species or size Captured contaminants are digested by the system and converted to water carbon dioxide and any elemental components present in the captured compounds which fall to the bottom of the tank and can be disposed of as a natural harm less byproduct 12 Periodic cleaning procedure Approximately every 120 days the de...

Page 11: ...gulations 8 Replace the BioStack filter in the tank 9 With a soft brush or rather with a vacuum cleaner vacuum the inside of the lid to clean the fan 10 Place the lid on the side of the tank and reconnect the cable screwing the connector 11 Insert the cover in its seat aligning it with the AIRcel70 logo connect the cable to the power supply and turn on themachine 13 Correct use 13 1 General 1 Remo...

Page 12: ...rials to clean the exterior surfaces of the appliance 6 Do not apply any voltage or frequency to the appliance other than those indicated in the specifica tions 7 Do not introduce liquids or other substances other than U Ox or water into the tank this could irreparably affect the performance of the appliance 13 3 Cleaning and care The customer may only carry out the cleaning and care of the device...

Page 13: ...rdous and the biomass is a non harmful mixture of non genetically modified micro organisms and enzymes Non toxic non flammable non pathogenic INGREDIENTS 60 water 40 Biomass Contains lipolytic enzymes and non pathogenic non toxic cultures of bacteria in a water base CAS 7732 18 5 14 4 First Aid Measures General information if symptoms are present or in all cases of doubt seek medical attention Inh...

Page 14: ...g plastic packaging can be recycled 14 14 Transport information BY LAND ADR RID no danger BY SEA IMDG no limits in relation to regulations BY AIR ICAO TI IATA non dangerous goods 14 15 Other information The information contained within this safety data sheet is believed to be correct at the date of issue of this manual 15 AIRcel70 Warranty Conditions U Earth provides Customers with a limited warra...

Page 15: ...oning of the units if decided independently by the end user e The Customer shall ensure that all system operating data including troubleshooting and maintenance is regularly recorded monitored archived and documen ted in a systematic manner from system start up This data must be made available to U Earth upon request in the event of a warranty claim f Prior to installation and use the units must b...

Page 16: ...port it cannot be refunded The Customer is strongly advised to insure transportation for the full value of the item If the end user has used the unit improperly U Earth is not responsible for a refund a If any unit has manufacturing defects having been used in accordance with the performance warranty clauses it will be U Earth s responsibility to repair re manufacture or replace at its discretion ...

Page 17: ...the equipment must be dry and well ventilated The room must be able to maintain a more or less constant tempe rature neither too cold nor too hot Direct exposure to sunlight should be avoided in all cases Outdoor storage sites should be avoided at all costs Heat Sources appliances should be stored away from any heat source such as furnaces or boilers 16 ...

Page 18: ...in standards and technical regulations adopted EN ISO 12100 2010 Safety of machinery General principles for design Risk assessment and risk reduction Person authorized to store the technical files Name and surname Elisabetta Maggio Address U Earth Biotech Ltd Via Bandello 16 Milan Italy Place London Date 24 April 2019 Air Treatment and Purification Machine AIRcel70 Year 2016 Directive 2006 42 EC L...

Page 19: ...earthbiotech https www linkedin com company u earth biotechnologies https www youtube com channel UCcJCDP SE31SauWPTdF4p Q https it u earth eu newsletter Stay in touch Subscribe to our newsletter and follow us on social media 18 ...

Page 20: ...U Earth Biotech LTD 172 Fulham Road London SW10 9PR United Kingdom Via Matteo Bandello 16 20123 Milan Italy info u earth eu ...

Reviews: