background image

Alternatively, take your old electrical and electro-

nic equipment to a collection point near your 

place of residence. Contact your dealer for more 

information.

Please make sure that the old device is kept out of 

the reach of children until it is returned. 

6. Safety Instructions

The AIRcel70 complies with the prescribed safety 

regulations. Improper use may result in personal 

injury or property damage. 

Before using your AIRcel70, please read these 

operating instructions. They provide important 

information regarding AIRcel70 safety, operation, 

and maintenance. By doing so, you will protect 

yourself and prevent any damage to AIRcel70. 

Keep these instructions in a safe place and give 

them to any subsequent user.

7. Intended Use

1.

 AIRcel70 should not be used in explosive envi-

ronments. 

2.

 AIRcel70 should not be used outdoors. 

3.

 Use AIRcel70 only in dry environments. All other 

forms of use are prohibited. U-Earth shall not be 

liable for damages resulting from misuse or abuse.

4.

 Persons who are unable to safely operate AIRcel70 

due to their physical, sensory or mental state or due to 

their lack of experience or knowledge, should not use 

the device without the supervision or guidance of a 

responsible person. 

5.

 The temperature of the surrounding environment 

should not fall below 3°C or exceed 50°C as the 

AIRcel70 is not capable of operating optimally in 

such temperatures. At temperatures below 1-2°C, 

the device may be damaged. 

8. Technical safety

1.

 Before installing AIRcel70, check for any visible 

external damage. A damaged AIRcel70 must not 

be installed or operated. 

2.

 The electrical safety of AIRcel70 is only guaranteed 

when it is connected to an electrical system that com-

plies with safety regulations. It is very important that 

you check the essential safety requirements and, if in 

doubt, have an experienced electrician examine your 

electrical system. Connect the device only to legally 

compliant systems.

3.

 For safety reasons, do not use extension cords 

(fire hazard due to overheating). 

4.

 Defective components may only be replaced 

with original U-Earth spare parts. U-Earth guarantees 

that the safety requirements are fully met for these 

parts only. The use of non-original parts will impair 

the function of the device and does not guarantee 

safe operation.

5.

 Improper repairs can lead to unforeseeable risks 

for the user for which U-Earth is not responsible. 

Repair work must only be carried out by technicians 

authorized by U-Earth. Otherwise, no warranty 

claim can be made for the damage caused. 

6.

 If the connection cable is damaged, it must be 

replaced by technicians authorized by U-Earth in 

order to safeguard the user from any danger.  

7.

 In case of failure, the machine must be taken out 

of operation. During cleaning and maintenance, 

AIRcel70 must be unplugged from the power 

supply. 

8.

 Do not tilt the device during use. Water leaking 

into the device may cause a short circuit. 

9.

 Do not place objects on the AIRcel70. 

10.

 During operation of AIRcel70, the water level in 

the reservoir should be checked regularly. Water 

evaporates during the bio-oxidation process.

The water level should never fall below the mini-

mum level as this will cause the device to shut 

down to prevent damage to the pump.  

11.

 If AIRcel70 is left unused for long periods of 

time (e.g. during vacations), the water tank must 

be completely emptied. The device must be 

disconnected from the power supply. 

05

Summary of Contents for AIRcel70

Page 1: ...AIRcel70 INSTRUCTIONS FOR USE ...

Page 2: ... United Kingdom VAT GB311666618 PEC u earthbiotech legalmail it Registered office in Italy U Earth Biotech Ltd Via Matteo Bandello 16 20123 Milan Italy C F 95209340108 P IVA 10920970968 More info on www u earth eu Contact service u earth eu Rev 22 September 2021 01 ...

Page 3: ...ntribution to the environment 5 Disposing of your device at the end of its useful life 6 Safety instructions 7 Intended Use 8 Technical safety 9 Components 10 What s in the box 11 Using the AIRcel70 12 Periodic cleaning procedure 13 Correct use 14 U Ox Material Safety Data Sheet MSDS 15 AIRcel70 Warranty Conditions 16 Declaration of conformity ...

Page 4: ... can make up more than 98 of the total particulate matter These particles are the most harmful to humans as they can penetrate as far as the pulmonary alveoli U Earth is currently the most efficient system in the sector as it is able to capture the pollutants measured at the site in question by biodegrading the molecules unlike other technologies on the market that act only on certain pollutants A...

Page 5: ...AIRcel70 Do not allow children to play with the AIRcel70 put their hands in the fan or tip it over 4 Keep packaging film out of reach of children because of choking hazard 4 Your contribution to the environment Disposal of transport packaging The packaging protects AIRcel70 from damage during transport The packaging material is chosen from envi ronmentally friendly and disposable materials which m...

Page 6: ...fety of AIRcel70 is only guaranteed when it is connected to an electrical system that com plies with safety regulations It is very important that you check the essential safety requirements and if in doubt have an experienced electrician examine your electrical system Connect the device only to legally compliant systems 3 For safety reasons do not use extension cords fire hazard due to overheating...

Page 7: ...ply cable input voltage 100 240 Volt approx frequency 50 60 Hz 3 Pure Air Zone adhesive 4 Instructions for use 11 Using the AIRcel70 11 1 Installation To proceed with the installation of AIRcel70 follow the procedure described below 1 Installation operations must take place with no power supply 2 Remove the AIRcel70 from the box and store it in a suitable place or where indicated by your Air Quali...

Page 8: ...k filter from the tank 5c Remove the protections from the bottom of the BioStack filter these protections prevent damage to the pump during transport 5d Replace the BioStack filter in the tank 6 Add water to the center of the BioStack until it reaches the maximum level indicated on the metal plate Water should be poured through clean con tainers used only for water not previously used to hold othe...

Page 9: ...reating a Pure Air Zone Water evaporates during the bioxidation pro cess and must be supplied regularly You can choose to add a little water each day or a larger amount of water at regular intervals by following Step 3 through Step 9 skipping Step 7 NOTE To add small amounts of water you do not need to unscrew the connector and remove the cover completely just move the cover and lay it on its side...

Page 10: ...ithin a range that protects against all types of pollutants regard less of species or size Captured contaminants are digested by the system and converted to water carbon dioxide and any elemental components present in the captured compounds which fall to the bottom of the tank and can be disposed of as a natural harm less byproduct 12 Periodic cleaning procedure Approximately every 120 days the de...

Page 11: ...gulations 8 Replace the BioStack filter in the tank 9 With a soft brush or rather with a vacuum cleaner vacuum the inside of the lid to clean the fan 10 Place the lid on the side of the tank and reconnect the cable screwing the connector 11 Insert the cover in its seat aligning it with the AIRcel70 logo connect the cable to the power supply and turn on themachine 13 Correct use 13 1 General 1 Remo...

Page 12: ...rials to clean the exterior surfaces of the appliance 6 Do not apply any voltage or frequency to the appliance other than those indicated in the specifica tions 7 Do not introduce liquids or other substances other than U Ox or water into the tank this could irreparably affect the performance of the appliance 13 3 Cleaning and care The customer may only carry out the cleaning and care of the device...

Page 13: ...rdous and the biomass is a non harmful mixture of non genetically modified micro organisms and enzymes Non toxic non flammable non pathogenic INGREDIENTS 60 water 40 Biomass Contains lipolytic enzymes and non pathogenic non toxic cultures of bacteria in a water base CAS 7732 18 5 14 4 First Aid Measures General information if symptoms are present or in all cases of doubt seek medical attention Inh...

Page 14: ...g plastic packaging can be recycled 14 14 Transport information BY LAND ADR RID no danger BY SEA IMDG no limits in relation to regulations BY AIR ICAO TI IATA non dangerous goods 14 15 Other information The information contained within this safety data sheet is believed to be correct at the date of issue of this manual 15 AIRcel70 Warranty Conditions U Earth provides Customers with a limited warra...

Page 15: ...oning of the units if decided independently by the end user e The Customer shall ensure that all system operating data including troubleshooting and maintenance is regularly recorded monitored archived and documen ted in a systematic manner from system start up This data must be made available to U Earth upon request in the event of a warranty claim f Prior to installation and use the units must b...

Page 16: ...port it cannot be refunded The Customer is strongly advised to insure transportation for the full value of the item If the end user has used the unit improperly U Earth is not responsible for a refund a If any unit has manufacturing defects having been used in accordance with the performance warranty clauses it will be U Earth s responsibility to repair re manufacture or replace at its discretion ...

Page 17: ...the equipment must be dry and well ventilated The room must be able to maintain a more or less constant tempe rature neither too cold nor too hot Direct exposure to sunlight should be avoided in all cases Outdoor storage sites should be avoided at all costs Heat Sources appliances should be stored away from any heat source such as furnaces or boilers 16 ...

Page 18: ...in standards and technical regulations adopted EN ISO 12100 2010 Safety of machinery General principles for design Risk assessment and risk reduction Person authorized to store the technical files Name and surname Elisabetta Maggio Address U Earth Biotech Ltd Via Bandello 16 Milan Italy Place London Date 24 April 2019 Air Treatment and Purification Machine AIRcel70 Year 2016 Directive 2006 42 EC L...

Page 19: ...earthbiotech https www linkedin com company u earth biotechnologies https www youtube com channel UCcJCDP SE31SauWPTdF4p Q https it u earth eu newsletter Stay in touch Subscribe to our newsletter and follow us on social media 18 ...

Page 20: ...U Earth Biotech LTD 172 Fulham Road London SW10 9PR United Kingdom Via Matteo Bandello 16 20123 Milan Italy info u earth eu ...

Reviews: