USER GUIDE
Control Operation 5
u-line.com
SAFETY • INSTALLATION & INTEGRATION •
OPERATING INSTRUCTIONS
• MAINTENANCE • SERVICE
Energy Saver Mode
Energy Saver mode reduces overall energy consumption
by altering user set point, differential, lighting and tone
settings. When in Energy Saver mode a small leaf icon will
be displayed on the main screen.
1. To enter Energy Saver Mode, first select Energy Saver
from the Customer Menu.
2. Press to select “Off” in the menu.
3. Press .
4. Press or to change the selection from Off to On.
5. Press to confirm your selection.
6. To return to the Customer Menu, press and select
“Return to Menu”.
7. To cancel Energy Saver Mode simply return to the
Customer Menu, select Energy Saver and change “On”
to “Off”.
Languages
The U-Line 3000 Series of models supports a number of
display languages including English, Spanish, French and
German.
1. To change display language select Languages from the
Customer Menu.
2. Press to select “English”.
3. Press . “English” will begin to flash.
4. Press or to cycle through the available
languages.
5. Press to confirm your choice.
Sound Level
Audible alarms and alert tones support four different
Sound Level settings, High, Medium, Low, and Off.
To select a new sound level, enter the Sound Level Menu
from the Customer Menu.
1. Press to select the current sound level.
Up
Select
Down
Energy Saver Mode
Indicator
ROOT
50° F
DELI
36° F
Can be displayed in Celsius
Up
Select
Down
RETURN TO MENU
LANGUAGES
ENGLISH
Up
Select
Down
RETURN TO MENU
SOUND LEVEL
HIGH