USER GUIDE
Control Operation - Service 4
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
Relay Toggle
Relay toggle is used to manually switch the state of each
relay to test for proper operation. In addition to the AC
relays, DC switches may also be toggled. Relay toggle can
also be used to force the unit into a particular state. For
example, to force a 3036 into a cooling cycle activate
LVLV, Comp, F1, and F3.
To access Relay Toggle
4. Press to select “Relay Toggle”.
5. Press .
6. Press and to scroll through each relay and DC
output.
7. Press
to
toggle.
To exit the Relay Toggle menu press to select “Return
to Menu” and press to confirm.
Input Status
Input status displays the current state of each available
input.
To access Input Status
1. Press to select “Input Status”.
2. Press .
3. Press and to scroll through available
information.
To exit the Input Status menu press to select “Return
to Menu” and press to confirm.
ID
Description
Solution
Mull
Mullion Heater (Not Used)
AC
Cond
Fan (Not Used)
AC
Def
Defrost Valve (Not Used)
AC
Pan
Pan heater (Not Used)
AC
Comp
Compressor
AC
F1
Evaporator Fan
DC
F3
Condenser Fan
DC
L1
Zone Lighting
DC
Up
Select
Down
RETURN TO MENU
RELAY TOGGLE
MULL OFF
COND OFF
ID
Description
Type
Door
Door Switch
Open - Closed
Test Input
Factory Test Input
Open
Up
Select
Down
RETURN TO MENU
INPUT STATUS
DOOR OPEN
IN2 OPEN