USER GUIDE
Control Operation - Service 8
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
Fan Delay
The Fan Delay menu option allows the modification of fan
run times during and after a cooling cycle. In order to
allow time for the evaporator to properly cool, the
evaporator fan is delayed from starting with the cooling
cycle for a given amount of time. In order to remove as
much warmth as possible from the cabinet the evaporator
fan will continue to run at the end of the cooling cycle for
a given amount of time.
Fan Delay On=
“Fan Delay On” is the amount of time in minutes the fan
will be delayed from starting from the beginning of a
cooling cycle.
Fan Delay Off=
“Fan Delay Off” is the amount of time in minutes the fan
will continue to run at the end of a cooling cycle.
To access Fan Delay
1. Press to select “Fan Delay”.
2. Press .
To alter fan settings.
3. Press to select either “Fan Delay On” or “Fan Delay
Off” and press . The chosen option will begin to
flash.
4. Press or to change settings.
5. Press
to
confirm.
To exit Fan Delay, press to select “Return to Menu”
and press to confirm.
Showroom Mode
Showroom displays a number of features and allows the
unit to be powered on without running the cooling system.
To toggle showroom mode
1. Press to select “Showroom Mode”.
2. Press .
3. Press to select “Off” and press . “Off” will begin to
flash.
4. Press or to toggle between off and on.
5. Press
to
confirm.
If set to “on” showroom mode will begin immediately. To
exit showroom mode press and hold for 5 seconds and
release. The display will show a countdown to switching
the unit off. Press again and the unit will immediately
switch on retaining the presets from before it entered
showroom mode.
To exit the showroom mode menu, press to select
“Return to Menu” and press to confirm.
Up
Select
Down
RETURN TO MENU
FAN DELAY
FAN DELAY ON = 1
FAN DELAY OFF = 2
Up
Select
Down
RETURN TO MENU
SHOWROOM MODE
OFF