6
User’s Manual
The CLRCO2075 can be installed using a gravity drain or can use a
factory installed or equivalent drain pump.
Follow these guidelines when installing drain lines to prevent water from
flowing back into the ice maker storage bin and/or potentially flowing
onto the floor causing water damage:
Gravity Drain
• Drain lines must have a 5/8 inch inside diameter.
• Drain lines must have a 1 inch drop per 48 inches of run (1/4 inch
per foot) and must not create traps.
• The floor drain must be large enough to accommodate drainage
from all drains.
• Insulate the bin drain line to prevent condensation.
CLRCO2075 With Factory Installed Drain Pump
NOTE
Before installing your U-Line CLRCO2075 With Factory
Installed Pump, it is extremely important to check and test
all hose connections at the drain pump. There is a
possibility that hose connections may have loosened during
shipment.
To prevent accidental electrocution, make certain that the
floor surfaces surrounding the unit are dry whenever power
is removed from, or applied to the unit.
1. Make certain the unit is not plugged into an electrical outlet.
2.
Carefully push the power cord grommet (Figure 2) through the
hole in the back panel.
Figure 2
CLRCO002
WATER
DRAIN
!
WARNING
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 6