background image

www.U-LineService.com

6

06/2006

CO2175DWR — Ice Maker/Refrigerator

The drawer unit can be installed with an appliance or 
fixture located in front of it, as long as there is adequate 
clearance for the drawer to be opened and removed 
when servicing (see 

Figure 4

).

Note: 

U-Line recommends you consider additional 

clearance in front of the open drawer for convenience.

Other Site Requirements

Power Supply

The unit requires a grounded and polarized 115 VAC, 
60 Hz, 15A circuit (normal household current). See 

Electrical Specifications

 on 

Page 13

.

Water Supply

The unit requires a 1/4-inch OD water supply line and a 
shut-off valve. For more information see 

Page 12

.

Environmental Requirements

Many U-Line models are designed to operate in harsh 
outdoor/marine environments. Special considerations 
include the following:

• The units are designed to operate between 50°F (10°C) 

and 110°F (40°C). High ambient temperatures (110°F 
[40°C] or higher) may reduce the unit’s ability to reach 
low temperatures.

• For best performance, keep the unit out of direct 

sunlight and away from heat generating equipment.

• In climates where high humidity and dew points are 

present, condensation may appear on outside surfaces. 
This is considered normal. The condensation will 
disappear when the humidity drops.

• U-Line does not recommend installation of glass front 

models (Wine Captain

®

 wine storage models and 

Beverage Centers) as well as the Combo Drawer model 
(Refrigerator/Freezer/Ice Maker) outdoors, or in 
tropical climates where high humidity and dew point 
are present on a regular basis, unless air-conditioning 
(typical 72°F, 75%RH) will be used.

24" Min.

Figure 4

Summary of Contents for Combo CO2175DWR

Page 1: ...one 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2006 U Line Corporation 06 2006 CO2175DWR Combo Drawer Refrigerator Freezer Ice...

Page 2: ...s connection to the water supply Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber...

Page 3: ...les designed for the installation of full overlay drawer panels When full overlay panels will not be used replacement handles MUST be installed part number 26070 01 Stainless Steel units have drawers...

Page 4: ...le and counter cleaners If any surface discolors or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a non abrasive cloth Always clean in the direction of the grain Alwa...

Page 5: ...p to allow for the installation of the Anti Tip Kit see Page 14 WARNING The Anti Tip Kit must be installed on this unit before it is used Never use the drawers as steps or as a shelf to support more t...

Page 6: ...gned to operate in harsh outdoor marine environments Special considerations include the following The units are designed to operate between 50 F 10 C and 110 F 40 C High ambient temperatures 110 F 40...

Page 7: ...reduce the drawer s front clearance if the unit is installed facing an appliance or structure see Page 5 Cut the panel inserts to the following dimensions Custom 1 4 Dimensions Width 23 1 32 Height 12...

Page 8: ...move and save the two screws located at the ends of the handle see Figure 8 Remove the handle 3 Remove existing panel and cardboard spacer Discard the spacer Attaching the Full Overlay Panel 1 If user...

Page 9: ...emoving Existing Drawer Fronts 3 Starting at the corners and working toward the center push the drawer gasket back into place Go on to 5 Adjust Drawers Checking Drawer Alignment The unit s drawers are...

Page 10: ...aused by one of the slides being mounted too far forward on the unit s liner Minor Adjustment Note The mounting holes on the slide are slightly larger than the screws diameter 1 Loosen the slide s mou...

Page 11: ...mounting screws 2 Push the slide upward or downward to match the position of the other slide 3 Retighten the screws See Figure 21 4 Repeat the procedure with the other slide if necessary Severe Adjus...

Page 12: ...ng installation Note U Line recommends the use of copper tubing for installation The use of other types of tubing is not recommended due to potential aftertaste deterioration over time To connect to w...

Page 13: ...se an extension cord to connect power to the unit Go on to 8 Level the Unit Leveling Information IMPORTANT It is extremely important that the unit is level If it is not level the ice mold will not fil...

Page 14: ...revent the unit from tipping Make sure the mounting screws attaching the unit to the counter cabinet or wall are deep enough into the mounting surface to support the weight of the drawers and the item...

Page 15: ...t No initial adjustments are required Once installation and leveling is complete the unit is ready for initial start up and operation Open the top drawer press and hold the POWER icon see Figure 31 1...

Page 16: ...Removing the lower drawer s ice bucket Adjusting the upper drawer s organizer left to right or front to back Start Up Troubleshooting Problem Q Unit does not appear to turn on when POWER icon is press...

Page 17: ...itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises call the U Line Customer Care Center...

Reviews: