www.U-LineService.com
6
06/2006
CO2175DWR — Ice Maker/Refrigerator
The drawer unit can be installed with an appliance or
fixture located in front of it, as long as there is adequate
clearance for the drawer to be opened and removed
when servicing (see
Figure 4
).
Note:
U-Line recommends you consider additional
clearance in front of the open drawer for convenience.
Other Site Requirements
Power Supply
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A circuit (normal household current). See
Electrical Specifications
on
Page 13
.
Water Supply
The unit requires a 1/4-inch OD water supply line and a
shut-off valve. For more information see
Page 12
.
Environmental Requirements
Many U-Line models are designed to operate in harsh
outdoor/marine environments. Special considerations
include the following:
• The units are designed to operate between 50°F (10°C)
and 110°F (40°C). High ambient temperatures (110°F
[40°C] or higher) may reduce the unit’s ability to reach
low temperatures.
• For best performance, keep the unit out of direct
sunlight and away from heat generating equipment.
• In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
disappear when the humidity drops.
• U-Line does not recommend installation of glass front
models (Wine Captain
®
wine storage models and
Beverage Centers) as well as the Combo Drawer model
(Refrigerator/Freezer/Ice Maker) outdoors, or in
tropical climates where high humidity and dew point
are present on a regular basis, unless air-conditioning
(typical 72°F, 75%RH) will be used.
24" Min.
Figure 4