Leveling Information

IMPORTANT

It is extremely important that the unit sits on a level 
surface, as it does not have feet levelers. If it is not level, 
the ice mold will not fill evenly.

Use a level to check the 
levelness of the unit from 
front to back and from side 
to side. Level should be 
placed along top edge and 
side edge as shown (see 

Figure 20

). Go on to 

9 Install the Unit

.

Installation of the CO29A/CO29FF

1. Open the water supply valve in the main water source.

2. Plug in the power cord.

3. Gently push the unit into position. Be careful not to 

kink the water supply line or entangle the electrical 
cord. 

4. Re-check the leveling, from front to back and side to 

side. Make any necessary adjustments. The unit’s top 
surface should be approximately 1/8" below the 
countertop.

Grille Installation

1. Locate and remove the grille screw from the cabinet, 

using a standard blade screwdriver (or a 1/4" 
nutdriver). See 

Figure 21

.

2. Remove the control knob by pulling it away from the 

cabinet.

3. Identify the grille screw hole on the grille itself. It is 

located toward the top of the middle recessed section 
of the grille.

4. Place the two hook-hinges (located on the rear bottom 

side of the grille) onto the front lip of the unit base. 
Swing the grille up into position, aligning the grille 
screw hole on the grille to the grille screw hole on the 
cabinet. See 

Figure 22

.

8 Level the Unit

Check

Level

Figure 20

9 Install the Unit

Grille Screw

Figure 21

Summary of Contents for Combo CO29

Page 1: ...com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 CO29A and CO29FF Ice Maker Refrigerators I...

Page 2: ...ction to the water supply Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber for ass...

Page 3: ...d and water connection parts Complete and mail the Product Registration Card or register online at www U LineService com Once your unit is installed keep the User Manual and this Installation Guide in...

Page 4: ...t sits on a level surface as it does not have feet levelers If it is not level the ice mold will not fill evenly Product Dimensions Door Swing Clearances Information Units have a zero clearance for th...

Page 5: ...from cabinet two screws See Figure 5 Remove screws on opposite side of cabinet Figure 6 Note that there may be a nut behind one or both screws on either side 4 Install hinge on opposite side bottom of...

Page 6: ...1 Adjust door to assure proper seal Tighten upper and lower hinge screws securely 12 Replace three plastic plugs removed in Step 8 into holes on top of unit Replace screws in holes in bottom of unit o...

Page 7: ...not weigh more than 20 lbs Door Panel Installation Install the insert as follows CAUTION Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin with a Phillips head s...

Page 8: ...screws Go on to 6 Prepare Plumbing CAUTION Plumbing installation must observe all state and local codes All water connections MUST BE made by a licensed qualified plumbing contractor Failure to follo...

Page 9: ...5 Go on to 7 Prepare Power Supply Electrical Specifications CAUTION Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized rec...

Page 10: ...ntangle the electrical cord 4 Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 below the countertop Grille In...

Page 11: ...etween 4 and 5 Assure that setting was not altered in shipment No other adjustments should be necessary at this time For information about Adjusting the Temperature Control see the User Manual As soon...

Page 12: ...n Problem Q Water does not appear to be flowing into unit Solution A Check that the water is connected and turned on and the line is not obstructed Water coming into the unit may take an hour or more...

Reviews: