background image

www.U-LineService.com

4

02/2005

CO29A and CO29FF Ice Maker/Refrigerators

Your U-Line product has been designed for either free-
standing or built-in installation. When built-in, your unit 
does not require additional air space for top, sides or rear. 
However, the front grille must NOT be obstructed and 
clearance is required for water and electrical connections 
in the rear.

Note: 

Unit can NOT be installed behind a closed cabinet 

door.

Cut-Out Dimensions

Follow the cut-out drawing in 

Figure 1

. The 21-1/16" 

width allows 1/4" for ease in installation and removal of 
the unit. 24" is the counter depth in most installations. 
The unit is 24" deep including the door and handle (see 

Figure 2

). 

IMPORTANT

It is extremely important that the unit sits on a level 
surface, as it does not have feet levelers. If it is not level, 
the ice mold will not fill evenly.

Product Dimensions

Door Swing/Clearances Information

Units have a zero clearance for the door to open 
90° (see 

Figure 3

). U-Line recommends a minimum door 

clearance of 1/4" to accommodate the handle if the unit is 
right-hand hinged and installed next to a wall or similar 
type of structure.

Units require a minimum of 1" door clearance if installed 
flush with cabinet or wall and 9" clearance if installed 
adjacent to cabinet or wall if the unit is left-hand hinged 
for easy removal of ice bin. See 

Figure 3

.

3 Prepare Site

8"

24"

Minimum

21-1/16"

See Electrical

Specifications

for Power Supply

Typical

Counter

Height

34-1/4"

to

35-1/8"

Cut-Out

Height

28-5/8"

to

28-7/8"

Filler Panel (Not Provided by U-Line) –

May Be Added Above or Below Unit

to Enclose for a Built-In Look 

Figure 1

24"

Including

Handle

28-1/2"

20-13/16"

Figure 2

Summary of Contents for Combo CO29

Page 1: ...com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 CO29A and CO29FF Ice Maker Refrigerators I...

Page 2: ...ction to the water supply Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber for ass...

Page 3: ...d and water connection parts Complete and mail the Product Registration Card or register online at www U LineService com Once your unit is installed keep the User Manual and this Installation Guide in...

Page 4: ...t sits on a level surface as it does not have feet levelers If it is not level the ice mold will not fill evenly Product Dimensions Door Swing Clearances Information Units have a zero clearance for th...

Page 5: ...from cabinet two screws See Figure 5 Remove screws on opposite side of cabinet Figure 6 Note that there may be a nut behind one or both screws on either side 4 Install hinge on opposite side bottom of...

Page 6: ...1 Adjust door to assure proper seal Tighten upper and lower hinge screws securely 12 Replace three plastic plugs removed in Step 8 into holes on top of unit Replace screws in holes in bottom of unit o...

Page 7: ...not weigh more than 20 lbs Door Panel Installation Install the insert as follows CAUTION Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin with a Phillips head s...

Page 8: ...screws Go on to 6 Prepare Plumbing CAUTION Plumbing installation must observe all state and local codes All water connections MUST BE made by a licensed qualified plumbing contractor Failure to follo...

Page 9: ...5 Go on to 7 Prepare Power Supply Electrical Specifications CAUTION Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized rec...

Page 10: ...ntangle the electrical cord 4 Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 below the countertop Grille In...

Page 11: ...etween 4 and 5 Assure that setting was not altered in shipment No other adjustments should be necessary at this time For information about Adjusting the Temperature Control see the User Manual As soon...

Page 12: ...n Problem Q Water does not appear to be flowing into unit Solution A Check that the water is connected and turned on and the line is not obstructed Water coming into the unit may take an hour or more...