Checking Door Alignment

The unit’s door is aligned at the factory before shipment. 
However, its alignment could have been disturbed during 
shipment or during door panel installation.

IMPORTANT

Properly aligned, the door should be 1/8" below the top of 
the unit’s cabinet, NOT flush with the top (see 

Figure 27

).

1. Compare the top edge of the door to the top edge of 

the cabinet.

2. If the door edge is 1/8" below and parallel to the top of 

the cabinet, go on to 

6 Prepare Power Supply

. If it is 

not, note whether the side opposite the hinge needs to 
be moved UP or DOWN, and use the following 
procedure.

Note: 

If door is adjusted correctly, but panel is not square 

with the adjacent cabinets, slight adjustments can be 
made by drilling the holes in the vinyl coated steel panel 
slightly oversized. See 

Figure 21

 on 

Page

 

10

.

Adjusting Door Alignment

1. Remove top hinge screw 

pin (7/64" Allen wrench or 
Phillips screwdriver, 
depending on your unit’s 
construction, see 

Figure 28

). Remove door 

by tilting forward and 
lifting off bottom hinge 
pin.

2. With door upside-down, 

loosen but do not remove 
the two screws on the 
door’s bottom hinge plate.

3. See 

Figure 29

. If the top far edge of the door needs to 

move UP, move the hinge plate toward the outside of 
the door and retighten screws. If the top far edge of the 
door needs to move DOWN, move the hinge plate 
toward the inside of the door and retighten screws.

4. Mount the door to recheck alignment and repeat Steps 

2 and 3 if further adjustment is necessary.

5. When top edge of door is parallel to top edge of 

cabinet, remove the door and ensure the two screws 
are secure.

6. Remove the door closers from the bottom hinge, clean 

thoroughly and lubricate the mating surfaces with 
petroleum jelly.

7. Reinstall the closers, lining 

up the bosses with holes in 
hinge and hinge plate (see 

Figure 30

).

8. Mount the door, install top 

hinge pivot pin and go on 
to 

6 Prepare Power 

Supply

.

5 Adjust Door

1/8"

Figure 27

ULIN_0133_A

Figure 28

Notch

Slotted

Mounting

Holes

Raise

Outside

Door Edge

Lower

Outside

Door Edge

Figure 29

Door

Closer

Inserts

Boss

Figure 30

Summary of Contents for Echelon 2115RS00

Page 1: ...ineService com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2006 U Line Corporation 08 2006 2115R Refrigerator Installation...

Page 2: ...TANT PLEASE READ all instructions completely before attempting to install or operate the unit This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qua...

Page 3: ...place for future reference Your unit is Black White or Stainless Steel Black and White units have a reversible door with a slightly contoured handle across the top They come with a flush mounted door...

Page 4: ...lead to rust Some installations may require cleaning on a weekly basis Do not clean with steel wool pads Do not use cleaners that are not specifically intended for stainless steel this includes glass...

Page 5: ...by moving the hinge hardware to the opposite side The top hinge hardware will be used on the bottom of the other side and the bottom hinge hardware will be used on the top of the other side see Figur...

Page 6: ...ly The unit requires a grounded and polarized 115 VAC 60 Hz 15A circuit normal household current See Electrical Specifications on Page 13 Environmental Requirements Many U Line models are designed to...

Page 7: ...or accent the surrounding d cor a Custom 1 4 Insert or a Full Overlay If no custom door panel is used go on to 5 Adjust Door Custom 1 4 Door Panel Insert Door Panel Preparation A custom door panel ca...

Page 8: ...inge pin and install upper hinge screw Full Overlay Door Panel Door Panel Preparation A full overlay door panel completely covers the doorframe and handle to give a built in appearance See your U Line...

Page 9: ...Phillips screwdriver Remove the door by tilting forward and lifting off the bottom hinge pin 3 Pull door gasket out of the groove top edge of door only Start in the middle and pull outward moving tow...

Page 10: ...and secure with the two screws removed in Step 4 under Removing Existing Door 3 Attach Overlay cap to door opposite side of where hinges will be see Figure 23 Removed Door Panel Top of Wood Panel Bac...

Page 11: ...te IMPORTANT Pivot posts must be cleaned Closers must also be clean and greased to ensure proper operation 5 Place the modified door onto the pivot post 6 Position door and install the pivot post into...

Page 12: ...epending on your unit s construction see Figure 28 Remove door by tilting forward and lifting off bottom hinge pin 2 With door upside down loosen but do not remove the two screws on the door s bottom...

Page 13: ...apter Never use an extension cord to connect power to the unit Go on to 7 Level the Unit Leveling Information Note It is recommended that the unit is level 1 Use a level to check the levelness of the...

Page 14: ...ppropriate rib Door Shelves 1 First pull shelf up at a 45 angle then straight out see Figure 34 2 Choose new location and line up on bosses First push straight in then down at a 45 angle Installation...

Page 15: ...mation about Adjusting the Temperature Control see the Use and Care Guide Start Up Troubleshooting Problem Q Unit does not appear to turn on when POWER icon is pressed Solution A Make sure unit is plu...

Page 16: ...itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises call the U Line Customer Care Center...

Reviews: