background image

www.U-LineService.com

12

02/2005

CO2075FF — Ice Maker/Refrigerator

Checking Door Alignment

The unit’s door is aligned at the factory before shipment. 
However, its alignment could have been disturbed during 
shipment or during door panel installation.

IMPORTANT

Properly aligned, the door should be 1/8" below the top of 
the unit’s cabinet, NOT flush with the top (see 

Figure 26

).

1. Compare the top edge of the door to the top edge of 

the cabinet.

2. If the door edge is 1/8" below and parallel to the top of 

the cabinet, go on to 

6 Prepare Plumbing

. If it is not, 

note whether the side opposite the hinge needs to be 
moved UP or DOWN, and use the following procedure.

Note: 

If door is adjusted correctly, but panel is not square 

with the adjacent cabinets, slight adjustments can be 
made by drilling the holes in the vinyl coated steel panel 
slightly oversized. See 

Figure 21

 on 

Page

 

10

.

Adjusting Door Alignment

1. Remove top hinge screw 

pin (7/64" Allen wrench or 
Phillips screwdriver, 
depending on your unit’s 
construction, see 

Figure 

27

). Remove door by 

tilting forward and lifting 
off bottom hinge pin.

2. With door upside-down, 

loosen but do not remove 
the two screws on the 
door’s bottom hinge plate.

3. See 

Figure 28

. If the top far edge of the door needs to 

move UP, move the hinge plate toward the outside of 
the door and retighten screws. If the top far edge of the 
door needs to move DOWN, move the hinge plate 
toward the inside of the door and retighten screws.

4. Mount the door to recheck alignment and repeat Steps 

2 and 3 if further adjustment is necessary.

5. When top edge of door is parallel to top edge of 

cabinet, remove the door and ensure the two screws 
are secure.

6. Remove the door closers from the bottom hinge, clean 

thoroughly and lubricate the mating surfaces with 
petroleum jelly.

7. Reinstall the closers, lining 

up the bosses with holes in 
hinge and hinge plate (see 

Figure 29

).

8. Mount the door, install top 

hinge pivot pin and go on 
to 

6 Prepare Plumbing

5 Adjust Door

1/8"

Figure 26

Figure 27

Notch

Slotted

Mounting

Holes

Raise

Outside

Door Edge

Lower

Outside

Door Edge

Figure 28

Figure 29

Door

Closer

Inserts

Boss

Summary of Contents for Echelon CO2075FF

Page 1: ...vice com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 CO2075FF Ice Maker Refrigerator Insta...

Page 2: ...This unit requires connection to the water supply Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a...

Page 3: ...n a safe place for future reference Your unit is Black White or Stainless Steel Black and White units have a reversible door with a slightly contoured handle across the top They come with a flush moun...

Page 4: ...ions may require cleaning on a weekly basis Do not clean with steel wool pads Do not use cleaners that are not specifically intended for stainless steel this includes glass tile and counter cleaners I...

Page 5: ...the opposite side The top hinge hardware will be used on the bottom of the other side and the bottom hinge hardware will be used on the top of the other side see Figure 4 To reverse the door 1 Remove...

Page 6: ...op of door into position in top hinge and install top hinge screw pin 10 Install plastic screw plugs removed in Step 2 in old hinge holes 3 each top and bottom Other Site Requirements Power Supply The...

Page 7: ...ith or accent the surrounding d cor a Custom 1 4 Insert or a Full Overlay If no custom door panel is used go on to 5 Adjust Door Custom 1 4 Door Panel Insert Door Panel Preparation A custom door panel...

Page 8: ...door shelves by lining up the bosses and first pushing straight in then down at a 45 angle see Figure 37 on Page 15 Go on to 5 Adjust Door Full Overlay Door Panel Door Panel Preparation A full overlay...

Page 9: ...ter x 1 4 deep CAUTION It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed Installation Instructions Remov...

Page 10: ...es through both panels according to Figure 21 Remove tape adjoining the panels and enlarge the seven holes in the overlay panel using a 0 201 7 drill 3 If a user supplied cabinet handle will be used a...

Page 11: ...d hinge plate IMPORTANT Pivot posts must be cleaned Closers must also be clean and greased to ensure proper operation 5 Place the modified door onto the pivot post 6 Position door and install the pivo...

Page 12: ...screwdriver depending on your unit s construction see Figure 27 Remove door by tilting forward and lifting off bottom hinge pin 2 With door upside down loosen but do not remove the two screws on the d...

Page 13: ...tain that the tubing is not pinched or damaged during installation U Line recommends the use of copper tubing for installation To connect to water supply 1 Install the 1 4 inch OD copper water line fr...

Page 14: ...on cord to connect power to the unit Go on to 8 Level the Unit Leveling Information IMPORTANT It is extremely important that the unit is level If it is not level the ice mold will not fill evenly 1 Us...

Page 15: ...dge of shelf up 3 Keeping at this angle and hugging the right wall pull the shelf out 4 Choose new location and insert over ribs tilting right hand edge up Push in then lower shelf onto ribs Door Shel...

Page 16: ...e ice bucket Do not place cans or bottles so they are touching the back wall of the refrigerator section as they may freeze Do not place any objects over air inlet or outlet in the freezer section Abo...

Page 17: ...es U Line has distinguished itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises contact th...

Reviews: