18
Design
■
Features
■
Performance
U-LINE FROST FREE REFRIGERATION SYSTEM
Cooling Mode:
•
Bypass solenoid valve closed
•
Evaporator fan operating
•
Refrigerant flows through capillary tube
•
Normal vapor/compression cycle refrigeration
•
Drain heater off
Defrost Mode:
•
Bypass solenoid valve open
•
Refrigerant flows through bypass system
•
Vapor flows from condenser to evaporator without a phase change
•
Drain heater on
SOLENOID VALVE
CAPILLARY TUBE
VALVE IS CLOSED
FLOW WHEN SOLENOID
DRYER
CONDENSER
COMPRESSOR
EVAPORATOR
VALVE IS OPEN
FLOW WHEN SOLENOID
UL183-2
CO2075FF/2075RF & U-CO29FF MODELS