26
Design
■
Features
■
Performance
DISASSEMBLY PROCEDURES
Note:
Échelon models do not require removal of the ice maker or freezer housing to access the fan
motor, drain or evaporator.
To replace evaporator fan motor:
1. Disconnect unit from power source.
2. Remove 2 screws
(1)
from fan cover.
3. Remove 2 screws
(2)
holding fan bracket to liner.
4. Unplug fan connection.
5. Remove 2 nuts
(3)
holding the fan to the fan bracket.
6. Replace with new fan.
7. Plug in the fan connection.
8. Re-install fan bracket to liner making sure the fan wires are tucked behind the fan bracket.
9. Re-install unit and test.
To access evaporator or drain:
1. Disconnect unit from power source.
2. Remove 2 screws
(1)
from fan cover.
3. Remove 3 screws
(4)
from evaporator cover.
4. To remove, pull evaporator cover forward and turn.
1
4
4
2
2
3
U-LINE1004
CO2075FF/2075RF & U-CO29FF MODELS