background image

01/2007

9

www.U-LineService.com

2175BEV/2175BEVOL Beverage Center

5. If door has not been removed from cardboard 

packaging, carefully cut tape and remove from 
cardboard first. With bottom of door facing up, remove 
pivot plate (2 screws), flip over, and remount on 
opposite side of door (see 

Figure 11

). Be sure angled 

side of plate faces center.

6. Holding door upright with 

top of door tilted forward, 
place hole of door pivot 
plate on bottom hinge 
screw pin (see 

Figure 12

).

7. Tilt top of door into 

position in top hinge and 
install top hinge screw pin.

8. Install plastic screw plugs 

removed in Step 2 in old 
hinge holes (3 each, top 
and bottom).

Overlay Frame

(2175BEVOL Units Only)

Frame Preparation

An overlay frame covers the door frame to give a built-in 
appearance. Appropriate hardware and a copy of these 
instructions will be included in the unit.

IMPORTANT

The thickness of the wood overlay frame must be 3/4". 
The door frame must not weigh more than 20 lbs.

1. Create an overlay frame to the dimensions shown in 

Figure 13

.

IMPORTANT

Rear View of wood frame for right-hand hinge shown. 
Use mirror image for left-hand hinges.

2. Typical routing dimensions 

are shown in 

Figure 14

.

Figure 11

ULIN_0822_A

Figure 12

27-3/4"

30"

21-1/2"

23-3/4"

Rear View

of

Wood Frame

1/8"

13/16"

1/8"

Relief Notch for Pivot Plate
(Right Hand Hinge Shown)

3/4"

Figure 13

2-1/4"

1-13/16"

1-1/8"

11/16"

(Ref.)

7/16"

(Ref.)

5/32"

3/4"

3/8"

Figure 14

Summary of Contents for Echelon Series

Page 1: ...354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2007 U Line Corporation 01 2007 2175BEVS Beverage Center and 2175BEVOL Beverage Center...

Page 2: ...READ all instructions completely before attempting to install or operate the unit This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified elect...

Page 3: ...ion Card or register online at www U LineService com Once your unit is installed keep the Use and Care Guide and this Installation Guide in a safe place for future reference 2175BEVS units are Stainle...

Page 4: ...t could lead to rust Some installations may require cleaning on a weekly basis Do not clean with steel wool pads Do not use cleaners that are not specifically intended for stainless steel this include...

Page 5: ...units are designed to operate between 50 F 10 C and 110 F 40 C High ambient temperatures 110 F 40 C or higher may reduce the unit s ability to reach low temperatures For best performance keep the unit...

Page 6: ...ed so that the wood trim could be stained to match d cor or overlay frame The trim on the racks may be coated with a final finish or stained 2175BEVOL Models are designed for and require installation...

Page 7: ...e the inner liner of the unit to have a permanent odor which is not covered by the warranty If staining the trim is desired it must be done before the application of any type of final finish Review th...

Page 8: ...moving the hinge hardware to the opposite side The top hinge hardware will be used on the bottom of the other side and the bottom hinge hardware will be used on the top of the other side see Figure 7...

Page 9: ...old hinge holes 3 each top and bottom Overlay Frame 2175BEVOL Units Only Frame Preparation An overlay frame covers the door frame to give a built in appearance Appropriate hardware and a copy of thes...

Page 10: ...o ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed Installation Instructions Preparing Door Note Door is not attached It i...

Page 11: ...so can cause damage to overlay frame and or door Overlay frame will not sit flush to door if mounting hardware is not counter bored 3 Secure the front of the door to the back of the overlay frame usi...

Page 12: ...Adjust Door Checking Door Alignment The unit s door is aligned at the factory before shipment However its alignment could have been disturbed during shipment or during overlay frame installation IMPO...

Page 13: ...ectrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician The unit requi...

Page 14: ...ng adjust the rear feet to achieve a total unit rear height of 1 8 less than the opening s rear height Shorten the unit height in the front by adjusting the front feet This allows the unit to be gentl...

Page 15: ...not tripped Check to see that control is turned on Problem Q Light is on with door closed Solution A Touch the LIGHT icon on the display panel This will cancel out the light function and just allow th...

Page 16: ...itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises call the U Line Customer Care Center...

Reviews: