PAGE 3 OF 18
0623 IH-7935
ASSEMBLY
SETUP INSTRUCTIONS
NOTE: Floor scale was shipped with the four
threaded leveling feet adjusted for a flat and
even floor. The leveling feet are locked in place
with locknuts. See page 1 for height and level
adjustments.
1. Remove the screws from the junction box access
cover plate and remove the cover plate.
(See FIgure 2)
2. Pull indicator out from junction box for use.
3. Replace junction box cover plate and secure screws.
CONNECTING POWER
WARNING! Only use the original power plug
and battery that came with the scale. Using
an alternative power plug or battery could
damage the scale.
POWER PLUG
Plug the power plug into a standard 110V outlet.
BATTERY
The scale is equipped with a rechargeable battery.
When the battery voltage is low, a battery indicator
symbol
Lobat
will appear in the lower right hand corner of
the display.
CHARGING THE BATTERY
When the battery indicator symbol
Lobat
appears in the
lower right hand corner of the display, the battery needs
to be recharged.
Plug the power plug into the wall to charge the battery.
Allow 3-4 hours to fully charge battery. Scale does not
need to be turned on.
BATTERY MAINTENANCE
To keep the battery in good condition, simply discharge
the battery every month and fully recharge.
If the scale is not used for an extended period of time,
remove the battery from the battery compartment to
avoid leakage. Store the battery in a sealed bag or box
in a dry, temperate environment.
MODEL/SERIAL NUMBER LOCATIONS
The model identification label is located on the side of
the frame, next to the junction box access plate. Include
both model number and serial number when making
inquiries or ordering parts.
CALIBRATION
This scale was calibrated at the factory.
DO NOT ATTEMPT
TO CALIBRATE THIS SCALE.
WARNING! Breaking, removing or tampering
with the lead seal that locks out the calibration
switch on the digital weight indicator will void all
warranties. Calibration is performed by certified
scale service agencies only.
Contact your local weights and measures service
agency for calibration services.
Figure 2
Junction Box Access Cover Plate
Top of Scale