1.  Set Timer Knob to lowest setting that produces a 

good seal for bag thickness. Thicker bags need a 

higher setting. (Always start with a low setting and 

increase gradually.) 

2.  Place end of bag under sealing arm and press the arm 

down gently but firmly, until the red sealing light is lit.

3.  The red light will go out when sealing is complete.

4.  When red light goes out, leave the arm down for  

2-4 seconds.

5.  Use the sliding cutter to cut excess material.

6.  Release the arm and remove bag.

CAUTION! Follow all warnings and instructions 
marked on the sealer.

1.  Unplug sealer from the outlet before cleaning or 

changing any parts.

2.  Do not rest anything on the power cord. Do not 

operate with a damaged power cord or plug.

3.  Only turn on sealer when operator is present.

4.  Never insert hand or fingers between the Sealing 

Jaws unless the unit is unplugged.

5.  Never touch the Heating Element with bare hands 

while the sealer is plugged in, while in operation or 

just finishing operation. The element stays HOT for a 

little while after each sealing cycle.

6.  Check for worn or broken parts before operating 

sealer. 

7.  Keep the unit clean. Do not use water. Silicone 

spray may be used to clean the unit. Make sure the 

unit is unplugged before cleaning.

8.  When changing the cutting blade, be careful of the 

sharp edge. Dispose of old blade in used blade 

container.

9.  To change the Teflon

®

 Tape, cover the entire surface 

under the Heating Element with Teflon

®

 Tape. Bend 

down excess Teflon

®

 Tape on both ends to prevent 

the Heating Element from breaking and shorting out 

the machine.

10. When replacing the fuse, use the exact size, voltage 

and amperage.

11. When replacing any parts, be sure to list the exact 

locations of the connections and the order of the 

different pieces.

SAFETY INSTRUCTIONS

OPERATING INSTRUCTIONS

ADDITIONAL INFORMATION

1.  The unit can be left plugged in. The unit is OFF unless 

the sealing arm is down.

2.  Always keep sealer clean and remove any residue 

found on the Platform and Teflon Cover. Silicone 

spray may be used.

3.  When replacing the Heating Elements, always  

check the condition of the bottom Teflon Tape.  

(See Page 2) A worn Teflon Tape will cause the 

Heating Element to short out, which can damage 

the element.

4.  Occasionally check the Rubber Pressure Pad for 

wear or burn. A damaged Pressure Pad affects the 

quality of the seal.

5.  Turn power OFF and unplug the unit before 

replacing any parts.

Para Español, vea páginas 4-6.

Pour le français, consulter les pages 7-9.

Summary of Contents for H-1254

Page 1: ...operating sealer 7 Keep the unit clean Do not use water Silicone spray may be used to clean the unit Make sure the unit is unplugged before cleaning 8 When changing the cutting blade be careful of the...

Page 2: ...verse of step 1 If bottom adhesive Teflon Tape is worn burned or ripped it needs to be changed See next step Teflon Tape keeps the element insulated from the sealer housing to ensure proper sealer ope...

Page 3: ...ealing and power lamp is on but sealing light does not turn on Microswitch not detected Defective microswitch Adjust the microswitch lever or microswitch position Replace microswitch Teflon cloth is b...

Page 4: ...de sellado 6 Compruebe que no haya partes desgastadas o rotas antes de poner la selladora en funcionamiento 7 Mantenga la unidad limpia No use agua Puede usar silic n en aerosol para limpiar la unida...

Page 5: ...a de Teflon est desgastada quemada o rasgada deber ser reemplazada Ver siguiente paso La cinta de Teflon mantiene la resistencia aislada de la carcasa de la selladora para garantizar un correcto funci...

Page 6: ...o detectado Microinterruptor defectuoso Ajuste la palanca del microinterruptor o la posici n del mismo Reemplace el microinterruptor La tela de Teflon est quemada Tiempo de calentamiento demasiado lar...

Page 7: ...avant d utiliser la scelleuse 7 Gardez l appareil propre N utilisez pas d eau Vous pouvez utiliser un vaporisateur au silicone pour nettoyer l appareil Assurez vous que l appareil est d branch avant...

Page 8: ...f inf rieur en TeflonMD est us br l ou d chir il doit tre chang Voir l tape suivante Le ruban en TeflonMD isole le fil chauffant du bo tier de la scelleuse pour assurer le bon fonctionnement du scella...

Page 9: ...Le microcontact n est pas d tect Le microcontact est d fectueux R glez le levier du microcontact ou sa position Remplacez le microcontact Le rev tement en TeflonMD est br l Le temps de chauffage est...