background image

0411 IH-2957

PAGE 1 OF 17

H-2957

AUTOMATIC STRETCH
WRAP DISPENSER

SYSTEM SPECIfICATIONS

MACHINE DIMENSIONS

Length

116"

Width

65"

Height

92"

Turntable Diameter

65"

Turntable Height from Floor

3 1/4"

Wrapping Height

80"

Operation Space

125 x 70 x 100"

Maximum Load Size

56 x 56 x 80"

Approximate Shipping Weight

1220 lbs

ELECTRICAL SPECIFICATIONS

• 120 VAC, 60 Hz, Single-phase, 15 AMP
• NEMA-12 rated electrical panel
• Operating temperature: +32˚F to +110˚F
• Lockable disconnect switch
• NEC wiring standard
• Programmable Logic Controller (PLC) with input/

output diagnostic lights

TURNTABLE SYSTEM

• Low Profile: ½ HP 3-phase AC motor, ½ HP AC 

frequency drive

• 20-30 loads per hour (spiral) 
• 12 RPM turntable maximum speed
• 4,000 lbs turntable maximum load capacity

FILM CARRIAGE / ELEVATOR SYSTEM

• ½ HP 3-phase AC motor, ½ HP AC frequency drive

• Adjustable raise and lower speeds
• Automatic height detection photoelectric sensor

FILM DELIVERY SYSTEM

• ¼ HP 3-phase AC motor, ½ HP AC frequency drive
• Adjustable film force
• 200% / 250% average pre-stretch level
• 10" diameter roll capacity
• 20" height roll capacity

CAUTION! Motor control equipment and 
electronic controllers are connected to 
hazardous line voltages. When servicing 
drive and controllers, there may be exposed 
components with housings or protrusions at or 
above line potential. Extreme care should be 
taken to protect against shock.

The user is responsible for conforming to all 
applicable code requirements with respect 
to grounding all requirements. Do NOT use 
extension cords to operate the equipment.

Disconnect AC input power before checking 
components, performing maintenance, 
cleaning up, and when the machine is not in 
use. Do NOT connect or disconnect wires and 
connectors while power is applied to circuit.

Wiring work should be carried out only by 
qualified personnel. There is a danger of 
electric shock or fire.

WARNING! Loose clothing must NOT be worn 
while the machine is in operation. Stay clear of 
moving parts while the machine is running.

Summary of Contents for H-2957

Page 1: ...ic sensor FILM DELIVERY SYSTEM HP 3 phase AC motor HP AC frequency drive Adjustable film force 200 250 average pre stretch level 10 diameter roll capacity 20 height roll capacity CAUTION Motor control...

Page 2: ...ional items are added Refer to assembly drawings shipped inside the electrical enclosure for more detail information Tower Control Box Stretch Selector Cover Photo Sensor Film Carriage Foot Security P...

Page 3: ...oor Both the ramp and the machine should be lagged to the floor Power and Safety Wiring Checks 1 Using a voltage meter check the AC voltage coming to the system to insure proper voltage is present 2 M...

Page 4: ...ob to change the pre stretch percentage Lift the knob for the high percentage or lower the knob for low percentage Standard percentages are 200 low and 250 high 4 To ensure safety and correct operatio...

Page 5: ...value to return to the previous value in the memory 5 STOP button Stops the motor could be hidden by door if function disabled Important See instructions for RUN STOP cover removal 6 RUN button Starts...

Page 6: ...y rFr is equal to stator frequency In performance law the output frequency rFr motor speed is equal to the estimated motor speed Range 400 to 400 Hz Hz LCr Motor Current Estimation of the effective mo...

Page 7: ...1 Assignment nO Not Assigned OCr Motor current OFr Output Frequency nO AO1t Analog Output 1 Type 10U 0 10VDC 0A 0 20mA 4A 4 20mA 0A CODE SUB CODE NAME DESCRIPTION Adjustment raNge factory setting bFr...

Page 8: ...tion YES SdC1 Automatic DC Injection Current 0 120 if nCr 70 tdC1 Automatic DC Injection Time seconds 0 1 30 s 0 5 s PSS PS2 Second Preset Speed Assignment nO Function inactive L1H Input L1 active hig...

Page 9: ...tor short circuit Short circuit or grounding at the drive output Ground fault during running status Commutation of motors during running status Significant current leakage to ground if several motors...

Page 10: ...d Process overload Check the process and the parameters of the drive to be in phase OLF Motor overload Triggered by excessive motor current Check the setting of the motor thermal protection check the...

Page 11: ...in communication on the Modbus network Check the connections of communication bus Check the time out Modbus time out ttO parameter Refer to the Modbus user manual SLF 2 SoMove communication Fault com...

Page 12: ...atic mode switch to Auto and press the Start button To raise or lower the film carriage manually switch to Manual Up or Manual Down and press the Start button To stop switch to Auto or press the Stop...

Page 13: ...STOP button wait for at least 60 sixty seconds before pulling the button back out This will allow the frequency drives to completely go off Applying Reinforcement Wraps Automatic operation can be pau...

Page 14: ...crews located in sprocket hubs bearing hubs and flanges 3 Check for oil leaks around the speed reducers 4 Check for dry seals at the bearings 5 Check for chain wear and proper tension on the power rol...

Page 15: ...turntable frequency drive The frequency drive is not functioning Push the STOP button Wait 60 seconds and then pull the button out Is the fault cleared The frequency drive is not connected properly t...

Page 16: ...ee the product The indicator light does not turn on as the turntable passes the home position If not clear obstructions and adjust sensor to pick up target Now does the indicator light turn on Adjust...

Page 17: ...set properly Refer to film loading diagram Use proper film Restore parameters as listed on the electrical schematics Restore parameters as listed on the electrical schematics The film does not stay at...