background image

0411 IH-2957

PAGE 7 OF 17

fREQUENCY DRIVE CONTINUED

PROGRAMMABLE FUNCTIONS

All functions have been Highlight factory set and 

tested. The factory settings listed in this manual are the 

drive manufacturer's factory setting, not the Highlight 

Industries factory settings. Refer to the Electrical 

Schematic Drive Parameters page for the Highlight 

factory settings. Some of the most commonly adjusted 

programmable functions (parameters) are listed below:

NOTE: Refer to the manufacturer's operation 
manual or website for complete lists and 
explanations.

CODE

SUB- 
CODE

NAME/DESCRIPTION

fACTORY  
SETTING

tCC

Type of Control:

2C – 2-wire control

3C – 3-wire control

2C

Al1-

Al1t

Analog Input 1 Type:

5U – 0-5VDC input voltage

10U – 0-10VDC input voltage

0A – 0-20mA current input

5U

r1

Relay Output 1 Assignment:

nO – Not assigned

FLt – No error detected

rUn – Drive run

FLt

AO1-

AO1

Analog Output 1 Assignment:

nO – Not Assigned

OCr – Motor current

OFr – Output Frequency

nO

AO1t

Analog Output 1 Type:

10U – 0-10VDC

0A – 0-20mA

4A – 4-20mA

0A

CODE

SUB- 
CODE

NAME/DESCRIPTION

ADJUSTMENT 
RANGE

fACTORY 
SETTING 

bFr

Standard Motor Frequency

50/60

50Hz

nPr

Rated Motor Power (% of drive rated HP)

0.5-1.2

1

UnS

Rated Motor Voltage

100-480V

230V

nCr

Rated Motor Current

plate

Varies

FrS

Rated Motor Frequency

10-400Hz

50 Hz

nSP

Rated Motor Speed

0-24000rpM

Varies

tFr

Maximum Frequency

10-400Hz

72 Hz

Ctt

Motor Control Type:

PErF – Performance, Sensorless Vector

Std – Standard, Volts/Hertz

PUNP – Pump, low torque

Std

UFr

IR Compensation:

Optimizes torque at very low speeds

25-200%

100%

SLP

Slip Compensation

0-150%

100%

StA

Frequency Loop Stability: Adjusts overshoots and oscillations at the end of 

acceleration or deceleration. A higher number decreases oscillations

0-100%

20%

FLG

Frequency Loop Gain: Adjusts the slope of the speed increase. A lower number 

decreases oscillations.

0-100%

20%

tUn

Motor Auto Tuning: Automatically tunes the drive to the motor profile

nO/YES/dOnE

nO

I_O MENU

drC MENU

Summary of Contents for H-2957

Page 1: ...ic sensor FILM DELIVERY SYSTEM HP 3 phase AC motor HP AC frequency drive Adjustable film force 200 250 average pre stretch level 10 diameter roll capacity 20 height roll capacity CAUTION Motor control...

Page 2: ...ional items are added Refer to assembly drawings shipped inside the electrical enclosure for more detail information Tower Control Box Stretch Selector Cover Photo Sensor Film Carriage Foot Security P...

Page 3: ...oor Both the ramp and the machine should be lagged to the floor Power and Safety Wiring Checks 1 Using a voltage meter check the AC voltage coming to the system to insure proper voltage is present 2 M...

Page 4: ...ob to change the pre stretch percentage Lift the knob for the high percentage or lower the knob for low percentage Standard percentages are 200 low and 250 high 4 To ensure safety and correct operatio...

Page 5: ...value to return to the previous value in the memory 5 STOP button Stops the motor could be hidden by door if function disabled Important See instructions for RUN STOP cover removal 6 RUN button Starts...

Page 6: ...y rFr is equal to stator frequency In performance law the output frequency rFr motor speed is equal to the estimated motor speed Range 400 to 400 Hz Hz LCr Motor Current Estimation of the effective mo...

Page 7: ...1 Assignment nO Not Assigned OCr Motor current OFr Output Frequency nO AO1t Analog Output 1 Type 10U 0 10VDC 0A 0 20mA 4A 4 20mA 0A CODE SUB CODE NAME DESCRIPTION Adjustment raNge factory setting bFr...

Page 8: ...tion YES SdC1 Automatic DC Injection Current 0 120 if nCr 70 tdC1 Automatic DC Injection Time seconds 0 1 30 s 0 5 s PSS PS2 Second Preset Speed Assignment nO Function inactive L1H Input L1 active hig...

Page 9: ...tor short circuit Short circuit or grounding at the drive output Ground fault during running status Commutation of motors during running status Significant current leakage to ground if several motors...

Page 10: ...d Process overload Check the process and the parameters of the drive to be in phase OLF Motor overload Triggered by excessive motor current Check the setting of the motor thermal protection check the...

Page 11: ...in communication on the Modbus network Check the connections of communication bus Check the time out Modbus time out ttO parameter Refer to the Modbus user manual SLF 2 SoMove communication Fault com...

Page 12: ...atic mode switch to Auto and press the Start button To raise or lower the film carriage manually switch to Manual Up or Manual Down and press the Start button To stop switch to Auto or press the Stop...

Page 13: ...STOP button wait for at least 60 sixty seconds before pulling the button back out This will allow the frequency drives to completely go off Applying Reinforcement Wraps Automatic operation can be pau...

Page 14: ...crews located in sprocket hubs bearing hubs and flanges 3 Check for oil leaks around the speed reducers 4 Check for dry seals at the bearings 5 Check for chain wear and proper tension on the power rol...

Page 15: ...turntable frequency drive The frequency drive is not functioning Push the STOP button Wait 60 seconds and then pull the button out Is the fault cleared The frequency drive is not connected properly t...

Page 16: ...ee the product The indicator light does not turn on as the turntable passes the home position If not clear obstructions and adjust sensor to pick up target Now does the indicator light turn on Adjust...

Page 17: ...set properly Refer to film loading diagram Use proper film Restore parameters as listed on the electrical schematics Restore parameters as listed on the electrical schematics The film does not stay at...

Reviews: