INSTALLATION

Gate x 1

Torsion Bar x 2

Square U-Bolt x 2

J-Bolt x 2

Round U-Bolt x 2

3/8" Flat 

Washer x 4

3/8-16  

Hex Locknut x 4

1/2-13 

Hex Nut x 4

Hex Head  

Cap Screw x 2

Hardware Package

MOUNTING BOLTS

DANGER! Death or serious injury may occur if 

improperly installed or used.

•  Installation can be dangerous.
•  Read all instructions thoroughly before installing.
•  Gate must be installed to prevent unintended 

passage or fall into elevation change or other 

hazard.

•  Gate must not open toward the elevation 

change or other hazard.

• Gate must fully close automatically.

•  Only install gate on metal safety railing systems 

that comply with OSHA 1910, ANSI A1264 and 

other applicable standards for guardrails.

•  Only install in applications where the top of 

the tube panel is 41" or higher. 

•  Take necessary precautions during the 

mounting process. 

•  Do not fully tighten mounting bolts until 

instructed to do so.

TOOLS NEEDED

7/16" Wrench (2)

9/16" Wrench

3/4" Wrench (2)

Rubber Mallet

Safety Glasses

Para Español, vea páginas 4-6.

Pour le français, consulter les pages 7-9.

Please read and save these instructions. Read carefully 

before attempting to assemble, install, operate or maintain 

the product described. Protect yourself and others by 

observing all safety information. Failure to comply with 

instructions could result in personal injury and/or death. 

Retain instructions for future reference. Assembly and 

installation of the adjustable safety gate can be inherently 

dangerous. Take all precautions neccesary during 

assembly and installation.

Summary of Contents for H-5615

Page 1: ...at comply with OSHA 1910 ANSI A1264 and other applicable standards for guardrails Only install in applications where the top of the tube panel is 41 or higher Take necessary precautions during the mounting process Do not fully tighten mounting bolts until instructed to do so TOOLS NEEDED 7 16 Wrench 2 9 16 Wrench 3 4 Wrench 2 Rubber Mallet Safety Glasses Para Español vea páginas 4 6 Pour le frança...

Page 2: ...eration of gate trim bolt ends to approximately 1 4 from locknut with hacksaw or cut off wheel and deburr DANGER A fall resulting in DEATH or SERIOUS INJURY may occur if gate is improperly installed or used Gate must be installed to prevent unintended passage or fall into elevation change or other hazard Gate must not open toward elevation change or other hazard DANGER A fall resulting in DEATH or...

Page 3: ...t so the outside edge of gate strike plate is aligned past the center of guardrail tube as illustrated in Figures 2 and 3 Gate width is adjustable in two inch increments 1 Remove gate sleeve hex head cap screws and locknuts from gate sleeve and tube panel 2 Slide gate tube panel in or out to set position Make sure the gate tube panel gate strike plate is positioned as shown in Figure 2 3 Align hol...

Page 4: ...nstalación No apriete los pernos de instalación por completo hasta que se le indique INSTALACIÓN 1 Puerta 2 Barras de Torsión PARTES 2 Pernos en J 2 Pernos en U Redondos 4 Rondanas Planas de 3 8 4 Tuercas de Seguridad Hexagonales de 3 8 16 4 Tuercas Hexagonales de 1 2 13 2 Tornillos de Cabeza Hexagonal Paquete de Tornillería PERNOS DE INSTALACIÓN 2 Pernos en U Cuadrados HERRAMIENTAS NECESARIAS 2 L...

Page 5: ...as del perno a aproximadamente 6 3 mm 1 4 de la tuerca con una sierra o esmeril PELIGRO Si la puerta se instala o usa de forma incorrecta puede ocasionar una caída con LESIONES SERIAS o la MUERTE La puerta debe instalarse para prevenir el paso no deseado o caídas hacia el desnivel o algún otro peligro La puerta no debe abrir hacia el desnivel o cualquier otro peligro PELIGRO Si la puerta se instal...

Page 6: ...ubo del pasamanos como se muestra en los Diagramas 2 y 3 El ancho de la puerta se ajusta en incrementos de 2 pulgadas 1 Retire los tornillos de cabeza hexagonal y las tuercas de la manga de la puerta y del panel del tubo 2 Deslice el panel del tubo de la puerta hacia adentro o hacia afuera para fijar la posición Asegúrese de que el panel del tubo de la puerta y la placa de tope de la puerta estén ...

Page 7: ...es précautions nécessaires lors du procédé de montage Ne pas serrer les boulons de montage à fond avant d y être invité à le faire INSTALLATION PIÈCES Battant x 1 Boulon en U carré x 2 Boulon en J x 2 Boulon en U arrondi x 2 Rondelle plate de 3 8 po x 4 Écrou freiné hexagonal de 3 8 16 x 4 Écrou hexagonal de 1 2 13 x 4 Vis d assemblage à tête hexagonale x 2 Trousse de matériel BOULONS DE MONTAGE B...

Page 8: ...iron 6 3 mm 1 4 po de l écrou freiné à l aide d une scie à métaux ou d une meule tronçonneuse puis ébavurer DANGER Une chute pouvant causer la MORT ou des BLESSURES GRAVES peut se produire si le battant n est pas installé ou utilié correctement La barrière doit être installé pour interdire le passage ou pour prévenir toute chute de changement de hauteur ou tout autre danger Le battant ne doit pas ...

Page 9: ...té tubulaire du garde corps comme illustré sur les Figures 2 et 3 La largeur du battant est réglable par intervalles de 5 cm 2 po 1 Retirez les vis d assemblage à tête hexagonale et les écrous freinés du manchon de battant et de l extrémité tubulaire 2 Glissez l extrémité tubulaire vers l intérieur ou l extérieur pour régler sa position Assurez vous que l extrémité tubulaire et la plaque d arrêt d...