TROUBLESHOOTING

SPECIFICATIONS CONTINUED

OPERATING ISSUE

RECOMMENDATIONS

Doesn't turn on.

Make sure wiring is properly connected to hand dryer.

If not properly connected, contact installer.

Turns on and off in error.

Check that nothing is obstructing the cavity.

Remove objects from cavity.

Continues to run after hands have been 

removed.

A two second delay after hands have been removed is normal.

Not drying hands properly.

Clear obstruction in inlet and monitor state of HEPA filter.

Follow maintenance recommendations.

Shuts off after a few seconds.

Check that nothing is obstructing the cavity.

Remove objects from cavity.

Water accumulates in the base of the dryer.

Make sure drain outlet is not blocked.

Clean and unblock drain outlet with provided wire brush.

Reflects a red light.

Water tank is full.

Empty water tank and replace. Once water tank is empty red 

light will turn off.

Flashes a red light in the upper part of the 

front panel, while all other lights are turned off.

Contact Uline Customer Service at 1-800-295-5510.

Turns off when in use and starts again.

Disconnect from power supply. Reconnect and wait six minutes 

before using.

π

  CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA

1-800-295-5510

uline.com

Regulations

This unit complies with the following directives/normatives: 1999/5/CE, 2004/108/CE, 2006/95/CE, 

2002/96/CE, 2011/65/CE.

Others

This unit has Bluetooth™ technology.

Standard 

Warranty

Five years for parts and one year for labor (see conditions).

Summary of Contents for H-7862

Page 1: ...re electricity is turned off at the main panel before installing maintaining or cleaning the hand dryer Dryer must be installed in accordance with the rules and applicable federal state and local laws including fire prevention Do not wire the hand dryer into the lighting circuit It must be protected by an independent circuit The dryer is intended to be permanently connected to a power supply and m...

Page 2: ...ction an automatic calibration of the capacitive sensors is performed lasting six minutes In order for calibration to be performed correctly the hand dryer should not be handled used or any object be brought into its vicinity during calibration WARNING To reduce the risk of fire electric shock or injury use dryer only in the manner intended by the manufacturer 1 Disconnect power source to hand dry...

Page 3: ... wall plate over anchors and insert screws Pull electrical cable through hole in center left of mounting display See Figure 2 7 Remove hand dryer from packaging and open front cover to install electrical cable See Figure 3 8 Open cover of connector box where cable to network will be installed See Figure 4 9 Pass electrical cable through hole from back to front See Figure 5 Figure 2 Figure 3 Figure...

Page 4: ...screws to close cover See Figure 7 12 Place hand dryer on wall bracket See Figure 8 13 Remove air intake filter and secure hand dryer through inner hole Insert filter and connect unit See Figure 9 14 After installation wait six minutes for electrical calibration then test hand dryer by placing hands inside drying cavity As soon as hands are removed air flow should stop Figure 6 Figure 7 Figure 8 A...

Page 5: ...r to loosen dirt and grime INSIDE CAUTION Shut off power to hand dryer at service connection Cleaning should be performed by qualified service personnel NOTE With normal use hand dryer will require cleaning once a year Heavier usage requires more frequent cleaning Lint on air inlet or other internal parts of hand dryer will reduce efficiency and shorten life of the working parts WATER TANK 1 When ...

Page 6: ...d wire brush to clean drain hole Figure 12 Electric System Input Voltage 110 120 V Frequency 50 60 Hz Nominal Power 1000 W Electric Current 9 A Type of Motor Universal Motor Speed 21 500 RPM Working Temperature 104 F Manufacturing Cover Material ABS Treated with biomaster silver biocide antibacterial additive Finish Various Colors Mounting Bracket Galvanized Steel Water Inlet Protection IPX2 Filte...

Page 7: ...ulates in the base of the dryer Make sure drain outlet is not blocked Clean and unblock drain outlet with provided wire brush Reflects a red light Water tank is full Empty water tank and replace Once water tank is empty red light will turn off Flashes a red light in the upper part of the front panel while all other lights are turned off Contact Uline Customer Service at 1 800 295 5510 Turns off wh...