background image

PAGE 3 OF 3

0519 RH-8041

OPERATING ISSUE

RECOMMENDATIONS

The machine does not start. 

Check the battery charge.

The suction motor does not work. 

Check the dirty water tank is not full.

Check the dirty water tank lever sensor is not blocked/

malfunctioning. 

Check vacuum motor fuse. (See Check Motor Fuses on page 2)

The machine leaves the floor wet.

Check the squeegee blades are not worn. 

Check there is no debris between the squeegee blades.

Check there is no debris in the suction hose.

Check the suction filter is undamaged and clean. 

The machine leaves stripes of wet floor. 

Check the floor has been swept before using the machine. 

Check there is no debris between the two squeegee blades. 

Check the squeegee blades are not worn. 

Check squeegee is correctly adjusted. 

Brush motor will not start.

Check brush motor fuse. (See Check Motor Fuses on page 2)

The brush motor thermal cutout has 

tripped; the motorhead has overheated. 

Release the brush lever button (LED off) and leave the machine 

to cool down for at least 45 minutes. 

TROUBLESHOOTING

MAINTENANCE CONTINUED 

π

  CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA

1-800-295-5510

uline.com

4.  Check the fuse to see if it is blown by looking in the 

fuse window. If the metal wire is present and not 

broken, the fuse is good. If the metal wire is missing 

or broken, the fuse is bad and needs to be replaced 

with a new fuse. (See Figures 19-20)

5.  Install a new fuse, and reattach the fuse cover. 

Replace tank back on and test. (See Figure 20)

AUTOMATIC BRUSH REPLACEMENT

• Attaching: insert the brush under the head, activate 

the drive lever until it is attached. 

• Releasing: tilt machine back, activate drive lever 

and release

Figure 19

Figure 20