PAGE 10 OF 39
1121 IH-8184
ERROR CODES
ERROR CODE
DESCRIPTION
CAUSES
RECOMMENDATIONS
E01
The desk has an unknown
position and needs to be
initialized.
Position error.
New desk leg added.
Initialize the system.
E02
Overload in upward
direction has occurred.
Obstruction.
Bad leg or motor cable.
Check all cable
connections, initialize the
system.
Troubleshoot components
by initializing one at a time.
E03
Overload in downward
direction has occurred.
Obstruction.
Bad leg or motor cable.
Check all cable
connections, initialize the
system.
Troubleshoot components
by initializing one at a time.
E08
Indicate that software failed
to kick watchdog.
Program fault.
Unplug cable for fifteen
seconds.
Initialize the system.
Replace control box.
E09
Collisions detected on the
LINBUS.
Key pressed on two or
more connected handset
simultaneously.
Multiple LINBUS devices
activated.
Check if another desk panel
is connected and being
activated.
Unplug all but one desk
panel and test system.
E10
Power fail happened, or
power regulator adjusted
below 10%.
Power cord pulled during
driving.
Internal fault.
Only 1 battery for a 3- or
4-channel system.
Power fail, voltage on power
supply drops below a certain
limit, power removed.
Check cable is not caught,
and is allowed to freely
travel.
Use strain-relief loop built
into control box.
Use a second battery or
charge batteries.
E11
Change in number of
actuators since initialization.
Disconnection.
Desk Leg added.
Check motor cable
connections and Integrity.
Change motor cable or
desk leg.
Initialize the system.