PAGE 5 OF 18
0622 IH-7935
OPERATION
POWER ON/OFF
1. Press the
ON/OFF
key for two seconds to turn the
scale on or off.
CAUTION! Never power the scale on with weight
on the platform.
2. When turning on, the indicator will show
000000-999999 before entering weighing mode.
3. Check that the LCD display and the status lights are
working properly.
ZERO
INITIAL ZERO SETTING
When turning the scale on, if the weight on the display
indicator is within the initial zero tolerance, the indicator
will show
zero
.
MANUAL ZERO SETTING
1. Wait for the scale to stabilize.
2. Press the
ZERO
key. The display will show zero weight.
TARE
1. Press the
TARE
key.
2. The indicator will show the net weight. The Net and
Tare indicators will be displayed on the bottom of
the indicator.
3. Press the
TARE
key. Zero the weight.
4. The indicator will display the gross weight.
ACCUMULATION
1. Zero the weight. Load weight until the scale stabilizes.
2. Press the
TOTAL
key to enter accumulation mode.
3. Total indicator will be displayed on the bottom of the
indicator. Display will read
n 001
then will display
the loaded weight.
4. Unload the weight. Zero the weight. Load the
second weight until the scale stabilizes.
5. Press the
TOTAL
key. The display will read
n 002
,
then display the second loaded weight.
6. Repeat a maximum of 999 times.
CHECK THE ACCUMULATION
1. Press and hold the
key. Press the
TOTAL
key.
2. Display will read
n**
, then will show total weight.
NOTE: There are 8 digits total. The display
shows the first 4 digits, then the last 4 digits.
For example, when the first 4 digits displayed
are "0012" and the last 4 digits displayed are
"34.56," the weight is "1234.56."
EXIT ACCUMULATION
1. When the indicator shows the last 4 digits, press and
hold the
TOTAL
key. The indicator will read
clr n
.
2. Press the
key to exit. If you want to clear
the total weight, press the
ZERO
or
TARE
key. The
indicator will read
clr y
.
3. Press the
key to clear the total weight and exit
accumulating mode.
1. If the weight is stable, connect the scale to the
printer.
2. Press the
key.
NOTE: While in tare mode, print with tare. If the
scale shows a negative weight, printing is not
allowed.
COUNTING
Use this mode to count parts of uniform weight.
1. In weighing mode, remove all weight from the
platform.
2. Press the
COUNT
key to enter the counting mode.
PCS 0
will be shown on the display.
3. Press the
ZERO
key to change the sample quantity
– 5, 10, 20, 50, 100, 200 or 500 units.
4. Place the sample quantity of the item being
counted on the scale platform and press the
key. Sample quantity will be shown on the display.
5. Place remaining objects on the platform. The total
quantity will be shown on the display.
6. Press the
COUNT
key to return to weighing mode.
7. To weigh different weights, at weighing mode, put
the item on the scale and press the
COUNT
key. The
indicator will read
0
.
8. Press and hold the
COUNT
key. Press the
ON/OFF
key.
The indicator will show
PCS 0
.
9. Press the
ZERO
key and input the sample quantity.
10. Press the
key to enter. Repeat steps 2 and 3.