PAGE 2 OF 8 

0422 IH-9884

SAFETY

WARNING! Read all safety warnings before 
installing, making connections or servicing this 
scale. Failure to comply with these warnings 
could result in personal injury and/or property 

damage. Retain these instructions for future 

reference.

•  Verify that the AC adapters input voltage range 

and plug type are compatible with the local AC 
mains power supply.

•  Position the instrument so that the AC adapter can 

be easily disconnected from the wall socket.

•  Position the power cord so that it does not pose a 

potential obstacle or tripping hazard.

•  Operate the unit only under ambient conditions 

specified in these instructions.

•  Scale is for indoor use only.

•  Do not operate in hazardous or explosive 

environments.

•  Only use in dry locations.

•  Only use approved accessories and peripherals.

•  Disconnect from power supply when cleaning.

•  Service should only be performed by authorized 

personnel.

SETUP

TRANSPORTATION LOCK

1.  Rotate the 

pointer on the 

transportation lock 

to the unlocked 

position.  

(See Figure 1)

NOTE: 

Transportation 

lock is located 

on underside 
of scale.

LOCATION 

NOTE: Use on a firm, steady surface.

NOTE: Avoid locations with excessive air current, 
vibrations, heat sources or rapid temperature 

changes.

1.  Adjust the leveling feet so level bubble is centered in 

circle. (See Figure 2)

CONNECTING POWER

BATTERY

1.  Remove battery cover and install four C batteries 

using the polarity indications as shown in the battery 

compartment. (See Figure 3)

AC ADAPTER

NOTE: The AC adapter is used to power the 
balance when battery power is not needed.

2.  Connect the AC adapter plug to the input jack.  

(See Figure 3)

3.  Connect AC adapter (supplied) to the proper AC 

supply.

 

Figure 1

Pointer

Unlocked 

Position

Locked 

Position

Balanced

Unbalanced

Leveling  

Feet

Level  

Bubble

Figure 2

Battery 

Cover

Input Jack

Figure 3

Summary of Contents for H-9884

Page 1: ...e on Long Press when on Turns the scale off Short Press in Menu Selects accepts displayed setting Long Press Toggles through active units Short Press in Menu Toggles through available settings Short P...

Page 2: ...Disconnect from power supply when cleaning Service should only be performed by authorized personnel SETUP TRANSPORTATION LOCK 1 Rotate the pointer on the transportation lock to the unlocked position S...

Page 3: ...4 After pressing yes the scale will then display the stored sample size Press NO or BACK to toggle the choices 5 10 20 50 or 100 5 Put the indicated number of pieces on the pan Press YES to calculate...

Page 4: ...on procedure zero and span A span calibration is important when initially setting up the scale Lin LIN yes no Initiates a linearity calibration procedure zero mid point and span SETUP SUB MENU Back Li...

Page 5: ...he menu must be turned on to be active NOTE Available units and modes vary by model and local regulations SECURITY SWITCH Menu Lock switch may be used to limit changes to the user menu See Figure 4 Th...

Page 6: ...nge exceeded Clear pan check shipping lock setting Err 8 2 LoAd Power on zero under range Install pan check shipping lock setting Err 8 3 LoAd Overload Load exceeds scale maximum capacity Err 8 4 LoAd...

Page 7: ...des Weighing Parts Counting Checkweighing Power Requirement AC adapter included or four C batteries not included Typical Battery Life 270 hours 200 hours 270 hours Specified Temperature Range 50 F to...

Page 8: ...0 0001 21 574 x 0 001 Ounce oz 7 7600 x 0 0005 77 6025 x 0 0005 77 600 x 0 005 Ounce Troy ozt 7 0730 x 0 0005 70 7315 x 0 0005 70 730 x 0 005 Pennyweight dwt 141 46 x 0 01 1 414 63 x 0 01 1 414 6 x 0...

Reviews: