Control Operation - Dual Zone Beverage Centers

CONTROL FUNCTION GUIDE

FUNCTION

COMMAND

NOTES

ON/OFF

Press     and release

Unit will immediately turn On or OFF

Adjust Temperatures

Press      or      and release to adjust 

the lower zone. Press      to change 

to upper zone. Press     or      and 

release to adjust. 

Interior light color indicates zone temperature being set;
Blue = lower (38

o

 - 65

o

)

White = upper (38

o

 - 65

o

)

The upper temperature must be ≥ the lower temperature, 

maximum 20

higher.

Note: Adjusting the temperature in lower zone, may result 

in the upper zone automatically adjusting. When adjusting 

upper zone, control will not go beyond the maximum 

temperature spread.
See table on next page.

Toggle between ºF / ºC Hold      and     for 5 seconds

The display will change units

Leave interior light on

Press      and release to leave interior 

light on for 12 hours; press again to 

deactivate

After 12 hours, factory default is restored; light will turn on 

when door is open

Hide Display

Hold      and press

Display will turn off when door is closed. Unit will continue 

to operate. Repeat command to turn on display

Adjust light color

While holding      press and release  

to scroll through lighting options

   Option

Open Door

Closed Door

      00

White

White

0 1

 Blue

       Blue

02

       White      

      Blue

Light will be set at full intensity when door is open, and 

50% intensity when door is closed.

Enable Sabbath Mode

Press      and hold for 5 seconds and 

release

The oF / o

C symbol will flash briefly after 5 seconds. Inte

-

rior light and display will go dark and remain so until user 

resets mode - unit continues to operate     

Disable Sabbath Mode

Press 

and  release 

Display and interior light return to normal operation

Showroom Mode

Hold      and      for 5 seconds

The ºF / º

C symbol will flash. Display will be lit and interior 

light will function. Unit will not cool. Repeat command to 

return to normal operation

This unit is Star-K certified. See 

www.star-k.org for more details.

DOOR ALERT NOTIFICATION

When the door is left open for more than 5 minutes:

A tone will sound for several seconds every minute

will appear in display

Closed door to silence alert and reset

Summary of Contents for HWD524

Page 1: ...QUICK START GUIDE 5 CLASS DUAL ZONE 30616_D...

Page 2: ...re available worldwide U Line RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documen...

Page 3: ...product on u line com See complete warranty for details CONTENTS Safety and Warning 4 Environmental Requirements 5 Electrical 5 Door Swing 6 Door Adjustments 6 General Installation 7 Anti Tip Bracket...

Page 4: ...ure to follow this safety statement may result in minor or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regu...

Page 5: ...r or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adapter Altering cutting or re...

Page 6: ...erior NOTICE Properly aligned the door s gasket should be firmly in contact with the cabinet all the way around the door no gaps Carefully examine the door s gasket to ensure that it is firmly in cont...

Page 7: ...and side edge as shown 2 If the unit is not level adjust the legs on the corners of the unit as necessary 3 Confirm the unit is level after each adjustment and repeat the previous steps as needed INS...

Page 8: ...fit Also test to make sure the door opens and closes freely 3 Remove grille and place a mark on the floor at the front of the unit Also place a mark on the floor in the center of the unit 4 Remove th...

Page 9: ...drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door frame as a guide NOTICE It is important to ensure that all drilled holes are drilled to the correct depth in order t...

Page 10: ...pen Hide Display Hold and press Display will turn off when door is closed Unit will continue to operate Repeat command to turn on display Adjust light color While holding press and release to scroll t...

Page 11: ...GUIDE Dual Zone Temperature Table 11 Beverage Dual Zone Lower 33 45 Upper 38 65 Minimum Maximum 33 38 53 34 38 54 35 38 55 36 38 56 37 38 57 38 38 58 39 39 59 40 40 60 41 41 61 42 42 62 43 43 63 44 44...

Page 12: ...de Display Hold and press Display will turn off when door is closed Unit will continue to operate Repeat command to turn on display Adjust light color While holding press and release to scroll through...

Page 13: ...unit is progressing towards the selected temperature Time to reach set point varies based upon ambient temperature temperature of product loaded door openings etc U Line recommends allowing the unit t...

Page 14: ...agne and Magnum bottles only fit on wine racks when noted on the product specifications When determining capacities U Line uses typical 12 oz cans 12 oz bottles 750 mL white wine and red wine bottles...

Page 15: ...care when removing rack to avoid scratching interior of unit 5 Once removed retract the slides Note The slides on the rack have a thin coating which is used to block moisture and provide lubrication...

Page 16: ...interior of unit 5 Once removed retract the slides Note The slides on the frame have a thin coating which is used to block moisture and provide lubrication Use care when handling Installation 1 Insert...

Page 17: ...sconnect power to the unit Clean the interior and all removed components using a mild nonabrasive detergent and warm solution applied with a soft sponge or non abrasive cloth Cleaning Rinse the interi...

Page 18: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...

Reviews: