background image

QUICK START GUIDE

Environmental Requirements

This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
exposed to natural elements.

This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.

For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.

In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.

Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.

Electrical

SHOCK HAZARD — Electrical Grounding
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.

Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.

Altering, cutting or removing power cord,
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
and will void the warranty.

Never use an extension cord to connect power to
the unit.

Always keep your working area dry.

NOTICE
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit

interrupter) is usually not required for fixed location

appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.

CAUTION

!

5

Summary of Contents for HWD524

Page 1: ...QUICK START GUIDE 5 CLASS DUAL ZONE 30616_D...

Page 2: ...re available worldwide U Line RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documen...

Page 3: ...product on u line com See complete warranty for details CONTENTS Safety and Warning 4 Environmental Requirements 5 Electrical 5 Door Swing 6 Door Adjustments 6 General Installation 7 Anti Tip Bracket...

Page 4: ...ure to follow this safety statement may result in minor or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regu...

Page 5: ...r or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adapter Altering cutting or re...

Page 6: ...erior NOTICE Properly aligned the door s gasket should be firmly in contact with the cabinet all the way around the door no gaps Carefully examine the door s gasket to ensure that it is firmly in cont...

Page 7: ...and side edge as shown 2 If the unit is not level adjust the legs on the corners of the unit as necessary 3 Confirm the unit is level after each adjustment and repeat the previous steps as needed INS...

Page 8: ...fit Also test to make sure the door opens and closes freely 3 Remove grille and place a mark on the floor at the front of the unit Also place a mark on the floor in the center of the unit 4 Remove th...

Page 9: ...drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door frame as a guide NOTICE It is important to ensure that all drilled holes are drilled to the correct depth in order t...

Page 10: ...pen Hide Display Hold and press Display will turn off when door is closed Unit will continue to operate Repeat command to turn on display Adjust light color While holding press and release to scroll t...

Page 11: ...GUIDE Dual Zone Temperature Table 11 Beverage Dual Zone Lower 33 45 Upper 38 65 Minimum Maximum 33 38 53 34 38 54 35 38 55 36 38 56 37 38 57 38 38 58 39 39 59 40 40 60 41 41 61 42 42 62 43 43 63 44 44...

Page 12: ...de Display Hold and press Display will turn off when door is closed Unit will continue to operate Repeat command to turn on display Adjust light color While holding press and release to scroll through...

Page 13: ...unit is progressing towards the selected temperature Time to reach set point varies based upon ambient temperature temperature of product loaded door openings etc U Line recommends allowing the unit t...

Page 14: ...agne and Magnum bottles only fit on wine racks when noted on the product specifications When determining capacities U Line uses typical 12 oz cans 12 oz bottles 750 mL white wine and red wine bottles...

Page 15: ...care when removing rack to avoid scratching interior of unit 5 Once removed retract the slides Note The slides on the rack have a thin coating which is used to block moisture and provide lubrication...

Page 16: ...interior of unit 5 Once removed retract the slides Note The slides on the frame have a thin coating which is used to block moisture and provide lubrication Use care when handling Installation 1 Insert...

Page 17: ...sconnect power to the unit Clean the interior and all removed components using a mild nonabrasive detergent and warm solution applied with a soft sponge or non abrasive cloth Cleaning Rinse the interi...

Page 18: ...improper use maintenance installation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guid...

Reviews: