background image

USER GUIDE

Integrated Panel Dimensions 2

u-line.com

SAFETY •

INSTALLATION & INTEGRATION

 • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

HANDLELESS INTEGRATED FRAME

The following procedure is designed to provide a finished, 
handleless frame for an 18" (450 mm) door that 
seamlessly integrates with its surrounding cabinetry. 
Prepare two 18" (450 mm) panels for 36" (900 mm) units.

NOTE: Many cabinet manufacturers provide a ready 
solution for a handleless, integrated design that can be 
easily applied to your U-Line 3000 Series model. Consult 
your cabinet manufacturer for applicable design and 
installation details. The cabinet manufacturer’s solution to 
this design and integration detail will often result in an 
integrated frame solution wherein the size of the panel/
frame may result in a height dimension taller than what 
we specify. This can be achieved provided the additional 
height is positioned above the appliance door.

NOTICE

The integrated frame aligns with the 
surrounding cabinetry and, due to differences in 
cabinetry, may not align perfectly with the door.

The appliance will need up to 34-1/2" (876 mm) 
to the underside of the counter to leave room for 
leveling adjustments.

A single prepared overlay with insert must not 
weigh more than 20 lbs (10 kg).

Integrated Frame Preparation

1. Cut the main panels to the dimensions below. For 

details, see the drawings on the next page. Unit 
requires two complete panels.

2. Create the top design for the handleless feature and 

the 1/8" (3 mm) notch for the insert(s) indicated on 
the Top Detail drawing, on the next page.

3. Prepare the insert(s) that will back up the handleless 

design. 

Wooden Insert –

 Cut 1/8" (3 mm) thick 

wooden insert(s) to the appropriate dimensions below.

4. Optional: Stain or finish frame and wooden insert to 

desired stain or color. Be sure to closely follow the 
instructions provided by the manufacturer.

NOTICE

If finishing panel or wooden insert, all sides 
must be finished to prevent warping.

5. Attach the insert to the frame. Wood glue or equivalent 

adhesive should be used to attach insert to frame.

Main panel width

Main panel height

17-5/8" (445 mm)

28-13/16" (732 mm)

Wooden insert width

Wooden insert height

17-5/8" (445 mm)

3-1/2" (89 mm)

Cutout

Integrated Frame

Main Panel

Wooden Insert

Top Design
and Insert Notch

Attach Wooden Insert

Summary of Contents for Modular 3000 Series

Page 1: ...USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Modular 3000 Series 3036RRGL 36 Glass Door Refrigerator RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Page 2: ...ontents SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Intro Installation Integrated Panel Dimensions Integrated Grille Plinth Dimensions Integrated Panel Installation Gril...

Page 3: ...or additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u li...

Page 4: ...tant to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed 1 Cut the panels to the dimensions listed in the diagram below Un...

Page 5: ...y with the door The appliance will need up to 34 1 2 876 mm to the underside of the counter to leave room for leveling adjustments A single prepared overlay with insert must not weigh more than 20 lbs...

Page 6: ...ERVICE Handleless Integrated Frame Dimensions 3 4 20 mm 28 13 16 732 mm 2 3 4 70 mm 2 3 4 70 mm R 5 8 R 16 mm 1 8 3 mm 1 4 6 mm Wooden Insert Notch Depth 1 8 3 mm 2 3 8 60 mm 7 8 22 mm Ref Top Detail...

Page 7: ...ed in the appropriate diagram on the next page Unit requires two complete panels 2 Optional Stain or Finish panel to desired stain or color Be sure to closely follow the instructions provided by the m...

Page 8: ...ted Panel Integrated Panel Integrated Frame Front Side Front Side 3 5 16 89 mm to 4 5 16 114 mm Floor Cabinet 3 5 16 89 mm 3 5 16 89 mm to 1 25 mm U Line Unit Extended Integrated Panel Extended Integr...

Page 9: ...ll integrated frame is 2 3 4 70 mm The top bottom border of the frame must account for any additional length BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT INTEGRATED FRAME FLAT AND WITHOUT INTERF...

Page 10: ...8 9 mm Height will vary from 3 5 16 84 mm to 4 5 16 110 mm based on your grille plinth strip base fascia height 2 Finish or stain your grille plinth strip base fascia panel to match your surrounding f...

Page 11: ...pe will not damage panel finish upon removal 7 Using a 7 64 3 mm drill bit drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door frame as a guide NOTICE It is important to...

Page 12: ...th strip base fascia rail with screw heads in base of unit 2 Push grille plinth strip base fascia rails towards the center of the unit and set rails over screw head 3 Slide grille plinth strip base fa...