background image

QUICK START GUIDE

4

u-line.com

Electrical

WARNING

!

SHOCK HAZARD — Electrical Grounding 
Required. Never attempt to repair or perform 
maintenance on the unit until the electricity has 
been disconnected.

Never remove the round grounding prong from 
the plug and never use a two-prong grounding 
adapter.

Altering, cutting or removing power cord, 
removing power plug, or direct wiring can cause 
serious injury, fire, loss of property and/or life, 
and will void the warranty.

Never use an extension cord to connect power to 
the unit.

Always keep your working area dry.

If the detachable type electric supply cord is damaged, it 
must be replaced by an equivalent cord available from the 
manufacturer or its service agent.

NOTICE

Electrical installation must observe all state and 
local codes. This unit requires connection to a 
grounded (three-prong), polarized receptacle 
that has been placed by a qualified electrician.

The unit requires a grounded and polarized 230 VAC, 
50 Hz, 8A power supply (normal household current). An 
individual, properly grounded branch circuit or circuit 
breaker is recommended. A GFCI (ground fault circuit 
interrupter) is usually not required for fixed location 
appliances and is not recommended for your unit because 
it could be prone to nuisance tripping. However, be sure 
to consult your local codes.

Water Hookup

PREPARE PLUMBING

The water valve uses a standard 1/4" (6.35 mm) 
compression fitting. U-Line recommends using accessory 
water hook up kit – part # WATERHOOKUP. The kit 
includes a 10' (3 m) braided flexible water supply line and 
a brass hose fitting. When using a 1/4" (6.35 mm) O.D. 
soft copper supply line use the brass nut and sleeve 
included with the unit.

WARNING

!

Prior to installation, determine if this product 
contains a gravity style drain or factory installed 
drain pump. Products without a drain pump may 
only use a gravity style drain. Failure to connect 
water supply or drain line connections properly 
may result in water leakage, personal injury, 
and/or property damage. Disconnect power and 
turn off water to the unit before attempting to 
alter these connections. These connections are 
the responsibility of the owner and must be 
connected per local plumbing code. If you are 
uncertain of how to safely and properly install 
this product, contact a licensed plumber. 

Water Supply Connection

WARNING

!

Connect to potable water supply only.

CAUTION

!

Review, obey, and understand the local 
plumbing codes before you install your unit. 
Connect to the cold water supply. The water 
pressure should be between 20 and 120 psi (138 
and 827 kPa). The water line MUST have a shut-
off valve on the supply line.

Summary of Contents for Modular 3045CLR

Page 1: ...QUICK START GUIDE Modular 3000 Series 3045CLR 220 240 V 50 Hz...

Page 2: ...TION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and do...

Page 3: ...1 Model List 2 Safety and Warning 3 Environmental Requirements 4 Electrical 4 Water Hookup 6 Drain 8 Door Swing 8 General Installation 9 Integrated Panel Installation 11 Control Quick Guide 11 First U...

Page 4: ...or more information Visit u line com to view detailed User Guides for all U Line products Clear Ice Machines U 3045CLRINT 00B U 3045CLRINT 40B Unit shown with wood panel not included with unit Visit h...

Page 5: ...hout this guide This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been given...

Page 6: ...enuine U Line replacement parts Imitation parts can damage the unit affect its operation or performance and may void the warranty This appliance is intended to be used in household and similar applica...

Page 7: ...for your unit because it could be prone to nuisance tripping However be sure to consult your local codes Water Hookup PREPARE PLUMBING The water valve uses a standard 1 4 6 35 mm compression fitting U...

Page 8: ...edges could be sharp 1 Turn off water supply and disconnect electrical supply to product prior to attempting installation 2 Remove the grille access panel in the front and the back panel 3 Locate wate...

Page 9: ...ker storage bin and or potentially flowing onto the floor which may result in personal injury or property damage NOTICE Drain can NOT be located directly below the unit Unit has a solid base that will...

Page 10: ...gravity drain you may have ordered a pre installed U Line P60 drain pump If you need to install a P60 drain pump into your unit see DRAIN PUMP section in the User Manual See below for typical install...

Page 11: ...utout opening adjust the rear legs to achieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the...

Page 12: ...e integrated panel to door using clamps A robust tape may also be used U Line recommends the use of bar clamps to secure the panel to the door If using tape be certain the tape will not damage panel f...

Page 13: ...ush against the bottom of the channel 11 Remove clamps from door NOTICE If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten s...

Page 14: ...nt at a time Allow ice maker production to stabilize for 24 hours before rechecking ice thickness Remove all ice from the storage bin Ice cubes in any given batch will vary so it is necessary to choos...

Page 15: ...ce thickness as follows 1 Press and hold for 5 seconds to enter the Customer Menu 2 Press to select Ice Adjust 3 Press The selection will begin to flash 4 Press to make the ice thicker or to make the...

Page 16: ...abor costs not specifically covered by this warranty shall be the responsibility of the purchaser This warranty extends only to the original purchaser of the U Line product The Product Registration Ca...

Page 17: ...U Line may require that defective parts be returned at your expense to the importer or directly to U Line located in Milwaukee Wisconsin USA for inspection Any action by you for breach of warranty mus...

Reviews: