background image

PAGE 5 OF 33 

0821 IH-5848

OPERATION CONTINUED

TARE CONTINUED

2.  Press the 

TARE

 button. The 

NET

 indicator will be 

displayed on the bottom of the display.

3.  The container's weight is then stored in the scale's 

memory and 

0

 is displayed.

4.  Add pieces to the container. As the pieces are 

added, their net weight will be displayed.

5.  Removing the container from the platform will 

cause the scale to display the container's negative 

number. Pressing the 

TARE

 button will readjust the 

scale to zero.

WEIGHING 

This mode is the factory default setting.

1.  If needed, press and hold 

MODE

 until 

WeIGH

 (weigh) 

is displayed.

2.  If required, place an empty container on the 

platform and press 

TARE

.

3.  Add a sample to the platform or container. The 

display shows the weight of the sample.

COUNTING 

This mode counts large numbers of items based on the 

weight of a reference count.

1.  Place an empty container on the platform and press 

TARE

 (if needed).

2.  Press and hold 

MODE

 until 

Count

 is displayed.  

CLr.PwW

 (clear average piece weight, APW) will then 

display. If no APW exists, the balance will display 

Put.10

, proceed to step 5.

3.  Press 

NO

 to use the stored APW. Proceed to step 7.

4.  Press 

YES

 to establish an APW.

5.  The balance will then display the stored sample size, 

i.e. 

Put 10

. Press 

NO

 or 

BACK

 to toggle the choices  

(5, 10, 20, 50 or 100).

6.  Put the indicated number of pieces on the platform 

then press 

YES

 to calculate the APW. The display 

shows the piece count.

7.  Add additional pieces until the desired count is 

reached.

8.  To clear the stored APW, press and hold 

MODE

 

until 

Count

 is displayed. Press 

YES

 when 

Clr.pwW

 is 

displayed.

NOTE: Press FUNCTION to view the current APW.

PERCENT WEIGHING 

This mode measures the weight of a sample as a 

percentage of a reference weight.

1.  If required, place an empty container on the 

platform and press 

TARE

.

2.  Press and hold 

MODE

 until 

Percnt

 is displayed.  

Clr.ref

 (clear reference) will then display. If no 

reference weight exists, the balance will display  

Put.ref

, proceed to step 5.

3.  Press 

NO

 to use the stored reference weight and 

proceed to step 6.

4.  Press 

YES

 to establish a new reference. Balance will 

now display 

Put.ref

.

5.  Add the desired reference material to the platform 

or container. Press 

YES

 to store the reference weight. 

The display shows 100%.

6.  Replace the reference material with the sample 

material. The display shows the percentage of the 

sample compared to reference weight.

7.  To clear the stored reference, press and hold 

MODE

 

until 

PERCNT

 is displayed. Press 

YES

 when 

C

lr.ref

 is 

displayed.

NOTE: Press FUNCTION to view the current 
reference weight.

CHECK WEIGHING 

Use this mode to compare the weight of items to a 

target weight range. The balance supports positive, 

negative and zero check weighing.

1.  Press and hold 

MODE

 until 

CHeCk

 (check) is 

displayed. 

CLr.ref

 (clear check limits) will then 

display. If no limits exist, the balance will display  

SEt.Lo

, proceed to step 4.

2.  Press 

NO

 to use the stored check limits and proceed 

to step 6.

3.  Press 

YES

 to establish new check limits. 

4.  The balance will then display 

Set.Lo

.

 Press 

YES

 to view 

the low limit value. Press 

YES

 to accept or 

NO

 to edit 

the low limit value. The stored value then displays with 

the first digit highlighted 

00.000 kg

.

 Repeatedly 

press 

NO

 until the desired number appears. Press 

YES

 

to accept and highlight the next digit. Repeat until all 

the digits are correct. Press 

YES

 to accept the low limit 

value, 

Set. Hi

 will be displayed.

5.  Repeat the same procedure to accept or edit the 

high value.

Summary of Contents for OHAUS SCOUT H-9596

Page 1: ...MENU FUNCTION Short Press YES Accepts the current setting on the display NO Advances to the next menu or menu item Rejects the current setting on the display and advances to the next available setting...

Page 2: ...to disconnect AC adapter from power receptacle Make sure that power cord does not pose a potential obstacle or tripping hazard For indoor use Operate only in dry locations Operate only under ambient c...

Page 3: ...rear of the balance Then connect the AC plug to an electrical outlet See Figure 5 BATTERY 1 Install four AA batteries with polarity as shown in the battery compartment See Figure 6 SECURITY SLOT 1 A...

Page 4: ...the pan C will be displayed while the reading is stored 6 The display will show donE if the calibration was successful The balance returns to the previous application mode and is ready for use LINEARI...

Page 5: ...ent APW PERCENT WEIGHING This mode measures the weight of a sample as a percentage of a reference weight 1 If required place an empty container on the platform and press TARE 2 Press and hold MODE unt...

Page 6: ...his mode allows the user to store a series of weight measurements Totalize mode has been initiated when the symbol is displayed and the current unit is displayed NOTE Only positive numbers are totaliz...

Page 7: ...ed position to prevent damage 1 Open the battery compartment cover and remove the weigh below hook See Figure 8 2 Attach the weigh below hook to the bottom of the scale through the weigh below hook ho...

Page 8: ...rtain regions USER MENU CALIBRATION MENU Enter this menu to perform calibrations SPAN Perform LINEARITY Perform END CALIBRATION Exit Menu SPAN Initiates a span calibration procedure zero and span L IN...

Page 9: ...weighing mode A OFF Set the automatic shut off functionality OFF Disabled 1 Powers off after 1 minute of no activity 5 Powers off after 5 minutes of no activity 10 Powers off after 10 minutes of no ac...

Page 10: ...GIT Set the graduation Settings of 0 5 1 2 5 10 100 are available NOTE Custom unit is locked at the off position when security switch is set to the locked position Follow instructions below to enter t...

Page 11: ...mode rEf Err Parts counting or percentage error sample weight 1d Balance shows error then exits parts counting or goes to Clr APU Lo rEf Percent Reference weight or APW is too low for accurate result...

Page 12: ...je MODE Modo Permite cambiar el modo de la aplicaci n MENU Men Ingresa el men de usuario FUNCI N DEL MEN Presi n corta YES S Acepta la configuraci n actual de la pantalla NO Avanza al siguiente men o...

Page 13: ...1 COLOCAR LA PLATAFORMA 1 En las balanzas con una plataforma rectangular este se coloca dentro de la subplataforma como se muestra y se gira en direcci n contraria a las manecillas del reloj hasta que...

Page 14: ...tomacorriente Vea Diagrama 5 RECARGABLE 1 Coloque cuatro bater as AA con los polos como se muestra dentro del compartimento de la bater a Vea Diagrama 6 RANURA DE SEGURIDAD 1 La balanza cuenta con una...

Page 15: ...asta que se muestre la palabra MENU Al liberar el bot n la pantalla mostrar C A L 3 Presione YES para aceptar Se mostrar el texto SPAN 4 Presione NO hasta que se muestre LIn 5 Presione YES para inicia...

Page 16: ...odo mide el peso de una muestra como porcentaje de un peso de referencia 1 Si es necesario coloque un contenedor vac o sobre la plataforma y presione TARE 2 Presione y mantenga presionado MODE hasta q...

Page 17: ...ept aceptar TOTALIZACI N ACUMULACI N Este modo permite al usuario almacenar una serie de mediciones de pesaje El modo Totalize totalizar se ha iniciado cuando se muestra en la pantalla el s mbolo adem...

Page 18: ...ompartimento de la bater a y quite el gancho de pesaje desde la parte inferior Vea Diagrama 8 2 Fije el gancho de pesaje desde la parte inferior a la base de la balanza a trav s del orificio para el g...

Page 19: ...ci n off apagada on encendida auto autom tico AUTO TARE Tarado Autom tico off apagado on encendido on acc encendidoacumulaci n AUTO OFF Apagado Autom tico off apagado 1 5 10 END SETUP Finalizar Config...

Page 20: ...nuto sin uso 5 Apagado autom tico tras 5 minutos sin uso 10 Apagado autom tico tras 10 minutos sin uso End Finalizar Avanza al siguiente men o permite regresar a la parte superior del men actual MEN D...

Page 21: ...1 x 10 2 1 divida el Factor entre 10 1 x 10 1 0 multiplique el factor por 1 1 x 100 1 multiplique el factor por 10 1 x 101 2 multiplique el factor por 100 1 x 102 3 multiplique el factor por 1000 1 x...

Page 22: ...je supera el l mite del cero inicial al encender Err 8 2 El pesaje est por debajo del l mite del cero inicial al encender Err 8 3 Sobrecarga el pasaje supera las capacidades clasificadas Err 8 4 Pesaj...

Page 23: ...u utilisateur FONCTION MENU Courte pression YES Oui Accepte le param tre actuellement affich l cran NO Non Acc de au menu ou l l ment du menu suivant Rejette le param tre actuellement affich et acc de...

Page 24: ...MBOLES DE L AFFICHAGE REMARQUE Selon le mod le il est possible que certains symboles ne soient pas disponibles CONFIGURATION S CURIT Sous plateforme Pointeur de verrou de transport Position verrouill...

Page 25: ...la balance Ensuite branchez la fiche secteur dans une prise lectrique Voir Figure 5 PILE 1 Installez quatre piles AA en veillant respecter la polarit comme indiqu dans le compartiment piles Voir Figu...

Page 26: ...MENU enfonc e jusqu ce que MENU soit affich Lorsque la touche sera rel ch e l cran affichera C A L 3 Appuyez sur YES pour accepter SPANsera alors affich 4 Appuyez sur NO jusqu ce que LIn soit affich...

Page 27: ...tage d un poids de r f rence 1 Au besoin placez un contenant vide sur la plateforme et appuyez sur TARE 2 Maintenez la touche MODE enfonc e jusqu ce que Percnt pourcentage soit affich Clr ref effacer...

Page 28: ...CUMULATION Ce mode permet l utilisateur d enregistrer une s rie de mesures de poids Le mode Totalize est lanc lorsque le symbole et l unit actuelle sont affich s REMARQUE Seuls les nombres positifs so...

Page 29: ...ercle du compartiment piles et retirez le crochet pour poids suspendu Voir Figure 8 2 Fixez le crochet pour poids suspendu dans le trou crochet pour poids suspendu situ sous la balance Voir Figure 9 3...

Page 30: ...TO TARE Tare automatique off d sactiv on activ on acc activ acc AUTO OFF Arr t automatique off d sactiv 1 5 10 END SETUP Terminer la configuration exit menu quitter le menu rESEt R initialise le menu...

Page 31: ...ge de v rification A OFF D finit la fonction d arr t automatique OFF D sactiv 1 S teint apr s 1 minute d inactivit 5 S teint apr s 5 minutes d inactivit 10 S teint apr s 10 minutes d inactivit End Pas...

Page 32: ...c e jusqu ce que MeNU s affiche Lorsque le bouton est rel ch l cran affichera C A L Appuyez sur NO lorsque vous serez invit s r viser les l ments de menu suivants C A L SEtUP ModE jusqu ce que Unit s...

Page 33: ...talonner Commutateur de s curit en position verrouill e Err 8 1 Le poids exc de la limite de la plage z ro Err 8 2 Le poids est sous la limite de la plage z ro Err 8 3 Surcharge le poids exc de la ca...

Reviews: