9. Gently slide upper hinge through flange and fasten 

upper hinge to unit (three screws). Partially tighten 
screws. See 

Figure 11

.

10. Place door on lower hinge pin.

11. Align door pivot hole 

with pivot hole in upper 
hinge and insert pivot 
screw into upper hinge 
and tighten securely. 
See 

Figure 12

.

12. Adjust door to assure 

proper seal. Tighten 
upper and lower hinge 
screws securely. 

13. Gently slide travel pin 

assembly through 
flange and then fasten 
to unit. Make sure 
travel pin in door 
engages the closer in the assembly, then tighten screws 
on travel pin assembly securely. See 

Figure 13

.

Other Site Requirements

Power Supply

The unit requires a grounded and polarized 110/115 VAC, 
60 Hz, 15A circuit (normal household current) or 220/230 
VAC, 50/60 Hz. See Electrical Specifications on 

Page

 

8

.

Water Supply

The unit requires a 1/4-inch OD water supply line and a 
shut-off valve. For more information see 

Page 7

.

Environmental Requirements

The surrounding air temperature must be at least 45°F 
(7°C) but must not exceed 110°F (40°C). Units may be 
installed outdoors in a covered area. The unit must not be 
located near heat-generating equipment or in direct 
sunlight.

Figure 11

Figure 12

Figure 13

Summary of Contents for Origins SP18

Page 1: ...one 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 SP18 Ice Maker for Marine or Recreational Vehicl...

Page 2: ...antial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber for assistance This unit requires connection to a grounded three pron...

Page 3: ...unction You have received a carton containing your SP18 Ice Maker with a package inside containing a User Manual a Product Registration Card and water connection parts Complete and mail the Product Re...

Page 4: ...nter depth in most installations 26 5 16 depth includes the door handle and water line connection see Figure 2 IMPORTANT It is extremely important that the unit sits on a level surface as it does not...

Page 5: ...ews on either side 5 Install hinge on opposite side bottom of cabinet See Figure 8 Replace nut on back side where installed Align hinge outer edge with cabinet before tightening screws 6 Relocate plas...

Page 6: ...el pin in door engages the closer in the assembly then tighten screws on travel pin assembly securely See Figure 13 Other Site Requirements Power Supply The unit requires a grounded and polarized 110...

Page 7: ...local codes All water connections MUST BE made by a licensed qualified plumbing contractor Failure to follow recommendations and instructions may result in damage and or harm WARNING To prevent accide...

Page 8: ...17 This will also safeguard against kinking the line 5 Go on to 6 Prepare Power Supply Electrical Specifications CAUTION Electrical installation must observe all state and local codes This unit requi...

Page 9: ...osition Be careful not to kink the water supply line or entangle the electrical cord 4 Re check the leveling from front to back and side to side Make any necessary adjustments 5 Secure the flange to t...

Page 10: ...n temperature for ice storage IMPORTANT It is possible that dirt or scale will dislodge in the water line Always throw away all ice cubes made during the first twenty four 24 hours of operation Start...

Page 11: ...es U Line has distinguished itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises contact th...

Reviews: