10
u-line.com
General Information
Air Flow
NOTICE
The unit requires proper air flow to perform at its highest
efficiency. Do not block the front grille, internal fans or vents
at any time, or the unit will not perform as expected. Do not
install the unit behind a door.
Initial Startup
All U-Line controls are preset at the factory. Initial startup requires
no adjustments.
NOTICE
U-Line recommends allowing the unit to run overnight
before loading refrigerator with product.
To power the unit on simply press POWER
and the unit will
immediately switch on. To turn the unit off, press and hold
POWER
for 5 seconds and release. The display will show a
countdown to switching the unit off.
U-Select
®
Control
Digital Display
The 3000 Series units are controlled by a feature rich, advanced
OLED display control unit. The control panel allows adjustment to
temperature set point, access to Energy Saver Mode, internal
temperature readings, and many other features.
Note:
A U-Line Control Simulator is available on-line. It is located on
the service website. To access this website you must have a user
name and password. Please go to http://www.u-line.com/control-
simulator/ to access the U-Line Control Simulator.
Adjusting Temperature Settings
Each zone has a series of Mode Settings with a default value for each
mode. Each mode setting can be further customized by fine tuning
the temperature set point. See the table below for a description of
each mode and mode temperature ranges. Mode selection will vary
by model.
Available mode settings will vary with model.
1. Press Select
to activate Mode Settings.
2. Pressing Select
will cycle through each available mode.
Reference the mode settings chart on pages
4
and
5
for each
setting’s default set point and range.
3. Once you have selected your desired mode, the default set
temperature will display. You may further fine tune the
temperature by pressing Up
or Down
.
Quick Chill
CAUTION
!
Quick chill is designed to quickly pull warm beverages and
foods down to optimum storage temperature. It is
important to only initiate quick chill modes when the unit
has been fully loaded with warm product.
To Initiate quick chill
1. Press Select
to select the desired mode setting.
2. Press Down
until the temperature set point reads “Quick”.
The quick chill feature will then begin for the period of time dictated
by the mode type. To cancel quick chill simply select a set point other
then “quick”.
Door Removed For Illustration Purposes
Internal Air Flow And Unit Ventilation Diagram
Mode Settings Chart
Setting
Default (°F)
Range (°F)
Red Wine
55°
55° - 65°
White Wine
50°
45° - 55°
Sparkling Wine
45°
38° - 50°
Beverage
38°
34° - 65°
Market
38°
34° - 40°
Root
50°
45° - 55°
Pantry
42°
34° - 70°
Deli
36°
34° - 40°