background image

1

U-Line 3000 Series Product Features

IMPORTANT

IMPORTANT

• PLEASE READ all instructions before installing, 

operating, or servicing the appliance.

• Proper installation procedures must be followed when 

completing an installation or relocation of a unit. 
Consult the installation guide before any installation 
begins. U-Line contact information appears on the rear 
cover of this guide.

• This unit requires connection to a dedicated 15 Amp 

grounded (three-prong), polarized receptacle. 
Receptacle should be installed by a qualified electrician, 
compliant with applicable electrical codes.

Safety Alert Definitions

Throughout this guide are safety items labeled with a Danger, 
Warning or Caution based on the risk type:

DANGER

Danger means that failure to follow this safety statement will 
result in severe personal injury or death.

WARNING

Warning means that failure to follow this safety 
statement could result in serious personal injury, 
property or equipment damage. 

CAUTION

Caution means that failure to follow this safety statement 
may result in minor or moderate personal injury, property 
or equipment damage.

2 Safety Precautions

General Precautions

Use this appliance for its intended purpose only. 

The 3000 model 

series is intended for BUILT IN installation only. Anti tip 
brackets MUST

 

be installed.

 Follow these general precautions 

with those listed throughout this guide:

DANGER

RISK OF CHILD ENTRAPMENT. Before you throw away your 
old refrigerator or freezer, take off the doors and leave shelves 
in place so children may not easily climb inside.

WARNING

SHOCK HAZARD - Electrical Grounding Required.
• Never attempt to repair or perform maintenance on 

the unit until the electricity has been disconnected.

• Never remove the round grounding prong from the 

plug and never use a two-prong grounding adaptor.

• Altering, cutting of power cord, removal of power 

cord, removal of power plug, or direct wiring can 
cause serious injury, fire and or loss of property and 
or life, and will void the warranty.

• Never use an extension cord to connect power to the 

unit.

• Always keep your working area dry.

WARNING

Install provided Anti-Tip kit on all models. Units 
may NOT be installed as free standing. Serious 
personal injury could occur.

CAUTION

• Use care when moving and handling the unit. Use gloves 

to prevent personal injury from sharp edges.

• If your model requires defrosting, DO NOT use an ice 

pick or other sharp instrument to help speed up 
defrosting. These instruments can puncture the inner 
lining or damage the cooling unit. DO NOT use any type 
of heater to defrost. Using a heater to speed up 
defrosting can cause personal injury and damage to the 
inner lining.

IMPORTANT

IMPORTANT

• Do not lift unit by door handle.
• Never install or operate the unit behind closed doors. 

Be sure front grille is free of obstruction. Obstructing 
free airflow can cause the unit to malfunction and will 
void the warranty.

• Failure to clean the condenser every six months can 

cause the unit to malfunction. This could void the 
warranty.

• Allow unit temperature to stabilize for 24 hours before 

use.

• Do not Block any internal Fans

Use only genuine U-Line replacement parts. Imitation 
parts can damage the unit, affect its operation or 
performance and may void the warranty.

Summary of Contents for U-3018WCOL-00

Page 1: ...VS 01 U 3036BVWCOL 00 U 3036BVWCS 00 U 3036BVWCS 13 U 3018RGLOL 00 U 3018RGLOL 01 U 3018RGLS 00 U 3018RGLS 01 U 3018RGLS 13 U 3018RGLS 15 U 3024RGLOL 00 U 3024RGLOL 01 U 3024RGLS 00 U 3024RGLS 01 U 30...

Page 2: ...Series 4 Door Swing Dimensions Other Site Requirements 5 Side By Side Installation 5 Power Supply 5 Environmental Requirements 5 3000 Series Doors Door Alignment and Adjustment 6 3000 Series Overlays...

Page 3: ...en may not easily climb inside WARNING SHOCK HAZARD Electrical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove th...

Page 4: ...S 00 U 3024BEVS 00 U 3036WCWCS 13 U 3024BEVS 01 U 3036RRS 00 U 3024RGLOL 00 U 3036RROL 00 U 3024RGLOL 01 Exterior Cleaning IMPORTANT IMPORTANT Stainless door panels handles and frames can discolor whe...

Page 5: ...unded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended GFCI ground fault circuit interrupter is us...

Page 6: ...33 11 16 To 34 11 16 35 7 16 23 7 16 3 5 8 To 4 5 8 Stainless Steel Overlay Door 33 11 16 To 34 11 16 35 7 16 23 7 16 3 5 8 To 4 5 8 Stainless Steel Solid Door 35 7 16 33 11 16 To 34 11 16 22 11 16 4...

Page 7: ...r a 1 4 inch of space needs to be maintained between the units to ensure unobstructed door swing Units must operate from separate properly grounded electrical receptacles placed according to each unit...

Page 8: ...pecial attention to the Cable Arm Make sure not to over extend or damage it during door alignment Stainless Models Removing Wrap 1 Open door completely 2 Remove the two wrap screws from the bottom of...

Page 9: ...lled Appliance will need up to 34 1 2 to the under side of the counter to leave room for leveling adjustments 1 Cut the panels to the dimensions listed in the appropriate diagram below 2 Optional Stai...

Page 10: ...working with the door that houses the display make certain the display cable remains securely seated in the inner door channel see below BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT OVERLAY PAN...

Page 11: ...g at the corners re install the gasket into the gasket channel in the frame Make sure the gasket is fully seated This may take some force 13 If installing an additional overlay on a 36 unit repeat ste...

Page 12: ...2 A Dimension A may vary from a minimum of 3 1 4 to a maximum 4 1 4 depending on toe kick height Measure toe kick height and cut overlay to same dimension Recommended Overlay Grille Thickness is 1 4 A...

Page 13: ...ompletely Make certain doors clear surrounding cabinetry 5 Using a 3 32 drill bit drill 6 pilot holes 3 for each bracket 5 8 deep into bottom of counter top Use the Anti tip brackets as a template The...

Page 14: ...ning cabinet side mounting screws will be installed later in this guide 3018 3024 Side Mount Side mount configurations work well if you have a granite counter top or do not wish to mount the brackets...

Page 15: ...any necessary adjustments The unit s top surface should be approximately 1 8 below the countertop 4 Install the 6 cabinet mounting screws for the Anti tip bracket 5 Remove the tape from the glass she...

Page 16: ...odels Combo Models a Refrigerator Freezer Refrigerators Drawers and Beverage Centers The U Line brand offers products in the 1000 Series 2000 Series and the Modular 3000 Series The 1000 Series offers...

Reviews: