U-Line Prepare Site
3
Your U-Line product has been designed exclusively for a built-in
installation. When built-in, your unit does not require additional air
space for top, sides, or rear. However, the front grille must NOT
be obstructed and clearance is required for an electrical
connection in the rear.
IMPORTANT
IMPORTANT
• Unit can NOT be installed behind a closed cabinet door.
Electrical Specifications
WARNING
SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from the
plug and never use a two-prong grounding adapter.
• Never use an extension cord to connect power to the
unit.
IMPORTANT
IMPORTANT
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A
power supply (normal household current). An individual, properly
grounded branch circuit or circuit breaker is recommended. GFCI
(ground fault circuit interrupter) is usually not required for fixed
location appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be sure to
consult your local codes.
See “Cut-Out Dimensions” for recommended receptacle location.
Cut-Out Dimensions
3018 Series
Follow the cut-out drawing. The 18" width allows for ease in
installation and removal of the unit. 24" is the cabinet depth in
most installations.
3024 Series
Follow the cut-out drawing. The 23-7/8" width allows for ease in
installation and removal of the unit. 24" is the cabinet depth in
most installations.
3036 Series
Follow the cut-out drawing. The 35 11/16" width allows for ease in
installation and removal of the unit. 24" is the cabinet depth in
most installations.
4 Prepare Site
4"
7"
24"
18"
33-7/8"
to
34-7/8"
4"
7"
24"
33-7/8"
to
34-7/8"
23-7/8"
4"
7"
24"
33-7/8"
to
34-7/8"
35 11/16"